background image

Adjusting the Settings

TIME

Sets the time that lights will remain on after the detection
zone is vacated. Adjustable from approximately 5 seconds to
12 minutes. The Factory Setting is 12 minutes.

PHOTOCELL 

For night-only operation, turn the knob completely 
counterclockwise to (to the MOON symbol). For 24-hour
operation turn the knob all the way clockwise to the
MOON/SUN symbol. Adjust counterclockwise to have the
sensor come on later at dusk, clockwise to have it come
on earlier.  The Factory Setting is Night-only (MOON).
If you set Evening Timer while set to 24 hour operation,
Evening Timer will begin immediately after flipping switch.

SENSITIVITY

Increases or decreases the responsiveness and range of
the sensor (adjustable from 30% to 100%).  The Factory
Setting is 100%.

Adjusting the Settings

EVENING TIMER

The STL360 provides an alternative to normal motion-
activated lighting. The EVENING TIMER can keep lights on
continuously – without motion – for 1 to 8 hours after dusk.
This is great for evening activities requiring continuous light.
During vacations the E

VENING

T

IMER

provides a “lived-in”

look  by simulating an occupant turning lights on at dusk,
and then off at bedtime.  

To set the EVENING TIMER, flip the wall switch controlling
the sensor three times slowly (off-on-off-on-off-on) within 3
seconds. If you set the EVENING TIMER during daytime,
the middle LED should start blinking, indicating that the
Evening Timer will start when dusk is detected.

Choose the length of time you want continuous lighting.
For example, if you set the EVENING TIMER to “8,” the
sensor will keep lights ON continuously for 8 hours after
dusk.  Once 8 hours have passed, the sensor will revert to
motion activated mode. At dawn, the photocell will detect
light and prevent lights from turning on 
during the daytime.

If you do not want to use the EVENING 
TIMER, do NOT flip the switch 3 times, 
as described above.

To end use of the EVENING TIMER, switch
OFF the power for at least 10 seconds, then
ON again. Sensor will be in Automatic Mode.
(After completing the warm-up period)

You can affix this label (right), provided, 
to your indoor light switch plate for easy 
reference.

12

TIME

1           8 HRS

5 SECS          12 MINS

–         +

EVENING
  TIMER

SENS

TIME

1           8 HRS

5 SECS          12 MINS

–         +

EVENING
  TIMER

SENS

TIME

1           8 HRS

5 SECS          12 MINS

–         +

EVENING
  TIMER

SENS

TIME

1           8 HRS

5 SECS          12 MINS

–         +

EVENING
  TIMER

SENS

11

Summary of Contents for STL360HBW

Page 1: ...ol Systems such as X 10 Leviton or Radio Shack are incompatible with sensors and may cause false activations Do not install sensors on a circuit that feeds motor loads such as kitchen appliances HVAC...

Page 2: ...vacated lights can be adjusted to remain on from approximately 5 seconds up to 12 minutes Since the lights are on only when needed and the sensor uses only one watt the STL360 is extremely energy effi...

Page 3: ...red by unwanted movement or heat source such as a swaying tree road traffic dryer vent swimming pool or hot tub To Improve Performance in Difficult Locations Reduce sensitivity by turning the SENS kno...

Page 4: ...high in the air over people s heads Choosing a Location Locate for Movement Across Pattern Check that movement is not directly towards sensor Sensor will see movement ACROSS its pattern more quickly C...

Page 5: ...ng screw Connect as shown in wiring diagram on page 7 6 Twist on wire nuts Secure with electrical tape 7 Align gaskets EZ Plate and metal mounting plate to insure proper seal Tighten EZ Plate center s...

Page 6: ...7 8 Strip 1 2 of insulation from all leads Connect as shown in wiring diagram 9 Twist on wire nuts Secure with electrical tape 10 Make sure all unused openings in EZ Plate are closed with plugs provi...

Page 7: ...IMER provides a lived in look by simulating an occupant turning lights on at dusk and then off at bedtime To set the EVENING TIMER flip the wall switch controlling the sensor three times slowly off on...

Page 8: ...s will appear when test mode ends If you require 2 more minutes of Test Mode turn the power off for at least 10 seconds and back on again In Test Mode no LEDs are lit MANUAL OVERRIDE MODE The STL360 h...

Page 9: ...not in Manual Override Mode Turn power OFF for 10 seconds then ON Sensor will be in Test Mode for approximately 2 minutes then it will switch to Auto Mode with lights off and ready to detect movement...

Page 10: ...attracted to the lights and fly close to the sensor causing triggering Reducing the sensitivity may help 9 Check Solutions 3 4 5 6 7 and 8 under If Lights Do Not Turn Off Technical Tips Lights Turn O...

Page 11: ...der using lower wattage energy saving lamps TIME 12 MINS SENS OK WRONG 1 Check that the sensor is level from side to side and pointed at the area you desire If unit is tilted part of the detection zon...

Page 12: ...ic We will repair or replace your unit Under no circumstances shall we be liable for any incidental or consequential damages arising out of or in connection with the use or performance of this product...