background image

Choosing a Location

Locations Near Roads

Cars and passing traffic may activate the sensor if it is
aimed at the road.

To Improve Performance in Locations Near Roads:

• 

Reduce sensitivity by turning the SENS knob 
counterclockwise.

• 

Mask the lens in the direction of 
the traffic using the lens mask 
provided or opaque tape. (Lens
mask can be broken along lines 
to desired size)

• 

Make sure that sensor is
not aimed at traffic. The
sensor should be aimed
down so that the maximum
range of the sensor ends at least 20’ 
from the road.  This will avoid detection 
of passing trucks and cars, or the air 
currents they create.

Mount Level

The sensor should be mounted level
from side to side and pointed at the
area where you desire coverage. If 
tilted, part of the detection zone may
be high in the air over people’s heads.

Choosing a Location

Locate for Movement Across Pattern

Check that movement is not
directly towards sensor. Sensor
will see movement ACROSS its
pattern more quickly. Check that
movement far away and directly
towards sensor is not entirely
within one zone. To fix, change
the sensor location.

If the sensor is located over 
a pathway so all movement is
directly toward it, range may
appear limited. “Micro Adjust”
sensor by moving 
sideways 1/4” or so, which
may reposition the zones
enough to allow earlier 
detection.

Choose a Protected Location  

Mount sensor in protected area.
The more protected the mounting
location, the less chance of lights
turning on occasionally during rain,
snow and windstorms because the
sensor is detecting dramatic
changes in temperature.

20' 

safety 

zone 

TIME

1           8 HRS

5 SECS          12 MINS

–         +

EVENING
  TIMER

SENS

Lens Mask

(included)

OK!

OK!

WRONG

Less

Sensitive

More Sensitive

Better detection after

“micro adjustment”

OK!

WRONG

6

5

Summary of Contents for STL360HBW

Page 1: ...ol Systems such as X 10 Leviton or Radio Shack are incompatible with sensors and may cause false activations Do not install sensors on a circuit that feeds motor loads such as kitchen appliances HVAC...

Page 2: ...vacated lights can be adjusted to remain on from approximately 5 seconds up to 12 minutes Since the lights are on only when needed and the sensor uses only one watt the STL360 is extremely energy effi...

Page 3: ...red by unwanted movement or heat source such as a swaying tree road traffic dryer vent swimming pool or hot tub To Improve Performance in Difficult Locations Reduce sensitivity by turning the SENS kno...

Page 4: ...high in the air over people s heads Choosing a Location Locate for Movement Across Pattern Check that movement is not directly towards sensor Sensor will see movement ACROSS its pattern more quickly C...

Page 5: ...ng screw Connect as shown in wiring diagram on page 7 6 Twist on wire nuts Secure with electrical tape 7 Align gaskets EZ Plate and metal mounting plate to insure proper seal Tighten EZ Plate center s...

Page 6: ...7 8 Strip 1 2 of insulation from all leads Connect as shown in wiring diagram 9 Twist on wire nuts Secure with electrical tape 10 Make sure all unused openings in EZ Plate are closed with plugs provi...

Page 7: ...IMER provides a lived in look by simulating an occupant turning lights on at dusk and then off at bedtime To set the EVENING TIMER flip the wall switch controlling the sensor three times slowly off on...

Page 8: ...s will appear when test mode ends If you require 2 more minutes of Test Mode turn the power off for at least 10 seconds and back on again In Test Mode no LEDs are lit MANUAL OVERRIDE MODE The STL360 h...

Page 9: ...not in Manual Override Mode Turn power OFF for 10 seconds then ON Sensor will be in Test Mode for approximately 2 minutes then it will switch to Auto Mode with lights off and ready to detect movement...

Page 10: ...attracted to the lights and fly close to the sensor causing triggering Reducing the sensitivity may help 9 Check Solutions 3 4 5 6 7 and 8 under If Lights Do Not Turn Off Technical Tips Lights Turn O...

Page 11: ...der using lower wattage energy saving lamps TIME 12 MINS SENS OK WRONG 1 Check that the sensor is level from side to side and pointed at the area you desire If unit is tilted part of the detection zon...

Page 12: ...ic We will repair or replace your unit Under no circumstances shall we be liable for any incidental or consequential damages arising out of or in connection with the use or performance of this product...

Reviews: