background image

TEX3500LCD

1

 

/ 54

USer Manual

Rev. 2.0 - 27/01/20

 

1.  Preliminary Instructions

• General Warnings

This equipment should only be operated, installed and 

maintained by “trained” or “qualified” personnel who are familiar 

with risks involved in working on electric and electronic circuits. 

“Trained” means personnel who have technical knowledge of 

equipment operation and who are responsible for their own 

safety and that of other unqualified personnel placed under 

their supervision when working on the equipment.   

“Qualified” means personnel who are trained in and 

experienced with equipment operation and who are 

responsible for their own safety and that of other unqualified 

personnel placed under their supervision when working on 

the equipment. 

 WARNING: Residual voltage may be present inside 

the equipment even when the ON/OFF switch is set to 

Off.  Before  servicing  the  equipment,  disconnect  the 

power  cord  or  switch  off  the  main  power  panel  and 

make sure the safety earth connection is connected. 

Some service situations may require inspecting the 

equipment with live circuits. Only trained and qualified 

personnel may work on the equipment live and shall be 

assisted by a trained person who shall keep ready to 

disconnect power supply at need.

R.V.R. Elettronica

  shall not be liable for injury to persons or 

damage to property resulting from improper use or operation 

by trained/untrained and qualified/unqualified persons.

 WARNING: The equipment is not water resistant. 

Any water entering the enclosure might impair proper 

operation. To prevent the risk of electrical shock or 

fire, do not expose this equipment to rain, dripping or 

moisture.

Please observe local codes and fire prevention rules when 

installing and operating this equipment.

  WARNING:  This  equipment  contains  exposed 

live parts involving an electrical shock hazard. Always 

disconnect power supply before removing any covers 

or other parts of the equipment.

Ventilation slits and holes are provided to ensure reliable 

operation and prevent overheating; do not obstruct or 

cover these slits. Do not obstruct the ventilation slits under 

any circumstances. The product must not be incorporated 

in a rack unless adequate ventilation is provided or the 

manufacturer’s instructions are followed closely.

 WARNING: This equipment can radiate 

radiofrequency energy and, if not installed in compliance 

with manual instructions and applicable regulations, 

may cause interference with radio communications.

  WARNING:  This  equipment  is  fitted  with  earth 

connections both in the power cord and for the chassis. 

Make sure both are properly connected.

Operation of this equipment in a residential area may cause 

radio interference, in which case the user may be required 

to take adequate measures.

The specifications and data contained herein are provided 

for information only and are subject to changes without 

prior notice. 

R.V.R. Elettronica

 disclaims all warranties, 

express or implied.While R.V.R. Elettronica attempts to 

provide accurate information, it cannot accept responsibility 

or liability for any errors or inaccuracies in this manual, 

including the products and the software described herein. 

R.V.R. Elettronica 

reserves the right to make changes to 

equipment design and/or specifications and to this manual 

at any time without prior notice.

• Notice concerning product intended purpose and use 

limitations.

This product is a radio transmitter suitable for frequency-

modulation audio radio broadcasting. Its operating 

frequencies are not harmonised in designated user countries. 

Before operating this equipment, user must 

obtain a licence to use radio spectrum from the 

competent authority in the designated user country. 

Operating frequency, transmitter power and other 

characteristics of the transmission system are subject to 

restrictions as specified in the licence.

  2. Warranty

La 

R.V.R. Elettronica 

warrants this product to be free from 

defects in workmanship and its proper operation subject to 

the limitations set forth in the supplied Terms and Conditions. 

Please read the Terms and Conditions carefully, as purchase 

of the product or acceptance of the order acknowledgement 

imply acceptance of the Terms and Conditions. 

For the latest updated terms and conditions, please visit our web 

site at WWW.RVR.IT. The web site may be modified, removed 

or updated for any reason whatsoever without prior notice. 

The warranty will become null and void in the event the 

product enclosure is opened, the product is physically 

damaged, is repaired by unauthorised persons or is used for 

purposes other than its intended use, as well as in the event 

of improper use, unauthorised changes or neglect.     

In the event a defect is found, follow this procedure:
1  Contact the seller or distributor who sold the equipment; 

provide a description of the problem or malfunction for 

the event a quick fix is available.  

Sellers and Distributors can provide the necessary 

information to troubleshoot the most frequently encountered 

problems.  Normally,  Sellers  and  Distributors  can  offer  a 

faster repair service than the Manufacturer would. Please 

note that Sellers can pinpoint problems due to wrong 

installation.
2  If your Seller cannot help you, contact 

R.V.R. 

Elettronica 

and describe the problem; if our staff deems 

it appropriate, you will receive an authorisation to return 

the equipment along with suitable instructions;

3  When you have received the authorisation, you may 

return the unit. Pack the unit carefully before shipment; 

use the original packaging whenever possible and seal 

the package perfectly. The customer bears all risks of 

IMPORTANT

The symbol of lightning inside a triangle placed on the product, evidences the operations for 

which is necessary gave it full attention to avoid risk of electric shocks. 

The symbol of exclamation mark inside a triangle placed on the product, informs the user 

about the presence of instructions inside the manual that accompanies the equipment, im-

portant for the efficacy and the maintenance (repairs).

Summary of Contents for TEX3500LCD

Page 1: ...TEX3500 TEX3500LCD LCD USER MANUAL VOLUME1 Manufactured by R V R ELETTRONICA Italy ...

Page 2: ... 2020 Revision History Date Version Reason Editor 27 01 2020 2 0 Second Version J H Berti Notification of intended purpose and limitations of product use This product is a FM transmitter intended for FM audio broadcasting It utili ses operating frequencies not harmonised in the intended countries of use The user must obtain a license before using the product in intended country of use Ensure respe...

Page 3: ...z tones 1 1ratio 75 kHz FM 0 05 Transient intermodulation distortion 3 18 kHz square wave 15 kHz sine wave 75 kHz FM 0 1 typical 0 05 Stereo separation 30Hz 53kHz dB 50 dB typical 60 RMS 75 kHz peak HPF 20Hz LPF 23 kHz 50 μS de emphasis L R demodulated dB 73 75 typical Qpk 75 kHz peak CCIR weighted 50 μS de emphasis L R demodulated dB 65 dB Qpk 40 kHz peak CCIR weighted 50 μS de emphasis L R demod...

Page 4: ...tput Connector BNC For RDS and isofrequency synchronizing purpose Impedance Ohm 5 k Output Level Vpp 1 Interlock Connector 2 x BNC Input and output for remote power inhibition short is RF off Service Connector DB9 F Factory reserved for firmware program Remote Interface Connector DB15F IIC 5 analog digital inputs 5 analog digital outputs FUSES On Mains 3 External F 10 T 6 x 30 mm On services On PA...

Page 5: ...dentification and Access to the Modules 32 6 1 Identification of the Modules 32 6 2 Spare parts 33 7 Working Principles 34 7 1 Power Supply 34 7 2 Interface board 34 7 3 Panel card 35 7 4 Main Board 35 7 5 Driver Board 35 7 6 Power amplifier 36 7 7 LPF Board 36 7 8 BIAS board 37 7 9 External Telemetry Interface Board 37 8 Maintenance and repair procedures 38 8 1 Introduction 38 8 2 Security Consid...

Page 6: ...iv User Manual Rev 2 0 27 01 20 TEX3500LCD This page was intentionally left blank ...

Page 7: ...ms all warranties express or implied While R V R Elettronica attempts to provide accurate information it cannot accept responsibility or liability for any errors or inaccuracies in this manual including the products and the software described herein R V R Elettronica reserves the right to make changes to equipment design and or specifications and to this manual at any time without prior notice Not...

Page 8: ... there is no heartbeat begin chest compressions immediately Figure 4 placing your hands in the centre of the victim s chest Figure 5 Figure 3 Figure 4 Figure 5 One rescuer give 2 quick rescue breaths after each 15 compressions Two rescuers one rescue breath after each 5 compressions Do not stop chest compressions while giving artificial breathing Call for medical help as soon as possible 3 1 2 If ...

Page 9: ...rmance characteristic is guaranteed in a range between 0 25 dB and 3 dB 5 and 50 referred to the nominal power of the equipment for example from 1750W to 3675W in case of TEX3500LCD outside these limits the equipment is able to work properly but can not guarantee an efficiency of 70 This transmitter incorporate a low pass filter to keep harmonics below the limits provided for by international stan...

Page 10: ...wer alarm Power Good feature Measurement and display of transmitter operating parameters Communication with external devices such as programming or telemetry systems via RS232 serial interface or I2 C Four LEDs on the front panel provide the following status indications ON LOCK FOLDBACK and RF MUTE The transmitter management firmware is based on a menu system User has four navigation buttons avail...

Page 11: ...MUTE Yellow LED lit when the transmitter s power output is inhibited by an external interlock command 5 CONTRAST Display contrast adjusting trimmer on the top of the equipment 6 POWER ON OFF switch 7 ESC Push button to exit from a menu 8 Push button to move in the menu system and to modify the parameters 9 Push button to move in the menu system and to modify the parameters 10 ENTER Push button to ...

Page 12: ...1 RDS input 14 RIGHT ADJ Adjustment trimmer for the Right channel input 15 RIGHT XLR connector balanced Right channel input 16 IMPEDANCE Dip switch to set the balanced input impedance 600Ω or 10kΩ 17 FUSE R Mains power supply fuse 18 SERVICE Reserved for future implementations 19 FUSE T Mains power supply fuse 20 FUSE S Mains power supply fuse 21 INPUT POWER Not used 22 R F OUTPUT RF output connec...

Page 13: ...U Reserved for future implementations XLR connector for AES EBU digital audio input 36 LEFT MONO ADJ Adjustment trimmer for Left Mono channel input 37 LEFT MONO XLR connector balanced Left Mono channel input 38 MAINS Connectors for 230 V 15 50 60 Hz mains power supply 4 5 Connector Pinouts 4 5 1 RS232 optional Type Female DB9 1 NC 2 TX_D 3 RX_D 4 NC 5 GND 6 NC 7 NC 8 NC 9 NC 4 5 2 Service for prog...

Page 14: ...nd 4 SDA IIC I O Serial data for IIC communication 5 VPA Tlm ANL OUT PA supply voltage 3 9V F S 6 FWD Tlm ANL OUT Forward power 3 9V F S 7 Power Good DIG OUT Indicates activation by switching the normally open contact to ground 8 GND Ground 9 GND Ground 10 Ext AGC RFL IN Ext signal 1 12V for limitation AGC 11 SCL IIC I O Clock for IIC communication 12 IPA Tlm ANL OUT PA supply current 3 9V F S 13 ...

Page 15: ...plicable law on workplace safety matter These companies must provide appropriate training to their staff on electrical devices and make sure that they familiarize themselves with the contents of this manual The respect of the safety instructions set forth in this manual or in the specified legislation does not exempt you from compliance with other specific regulations regarding installation place ...

Page 16: ...nvironmental conditions In case of the station where this device is located should be subjected to these physical events it is good to monitor these devices once you put it into service in addition to trying to protect the device itself as much as possible IMPORTANT never supply voltage to the equipment in presence of condensation This problem can occur more frequently in devices warehoused for a ...

Page 17: ...o forced ventilation The mounting surface must be able to withstand the weight of the device and must be sturdy Note below we will refer to a complete station where the device can be a part of it The same procedures also apply in case of the device is used individually The device is usually connected inside a 19 rack and fixed with M5 screws in the appropriate holes The equipment must be installed...

Page 18: ...he outlet air in the back of machine In this case provide adequate ventilation of the room COLD HOT 50cm In alternative is cooled by forced ventilation and the air outlet is located on the roof of machine Is recommended a length of tube approximetively of 1 5 meter COLD HOT 50cm ...

Page 19: ...he back or on the roof of the machine and conductors must be attached to the general disconnecting switch terminals Note The connection of machine to power supply is done by fixing a multi pole cable with exposed terminals to a terminal board Make sure with no possibility of error that the cable is not under tension when you connect it to the machine WARNING Is highly recommended to don t turn on ...

Page 20: ...ribution board R S T N PE Note the mains must be equipped with adequate earth connection properly connected to the equipment This is a pre requisite for ensuring operator safety and correct operation The following table shows the recommended cable cross sections CONNECTOR THREE PHASE CABLE SECTION SINGLE PHASE CABLE SECTION L Ø 2 5mm R Ø 1 5mm S Ø 1 5mm T Ø 1 5mm N Ø 2 5mm Ø 2 5mm PE Ø 2 5mm Ø 2 5...

Page 21: ...Vac mains power supply for TEX3500LCD with adequate earth connection For operating tests only dummy load with 50 Ohm impedance and adequate capacity minimum 3500W per TEX3500LCD Note to ensure the safety of the operators carry out the wiring according to the laws and regulations in force in the country where this equipment is installed Check that the POWER switch on the front and rear of TEX3500LC...

Page 22: ...qualified personnel This solution allows you to protect from violent atmospheric electric shocks that strike the surrounding ground up to several kilometers Provide an internal protection against interference on the distribution line such as EMI filters or stabilizers on line voltages rrequiring the installation in the distribution panel through qualified personnel which allow to filter the interf...

Page 23: ...ut connector when the equipment is switched on and no dummy load is connected Ensure that the POWER switch on the front panel of TEX3500LCD is set to OFF Connect the mains power cable to the MAINS connector on the rear panel Note the mains must be equipped with adequate earth connection properly connected to the equipment This is a pre requisite for ensuring operator safety and correct operation C...

Page 24: ... level set by the user and actual operating conditions such as temperature reflected power and other parameters Please read section 5 3 for more details of RF power modulation Access the Power Setup Menu pressing the following keys in the order ESC opens Default Menu ENTER hold down for 2 seconds Use the keys and in the SET menu to set transmitter output power the setting bar at the side of SET pr...

Page 25: ...di deviazione 0 dB Mono 37 36 13 13 dBm Input sensitivity in Stereo mode Ingresso Figura 6 2 Trimmer Sensibilità Nota SCA1 RDS 9 13 8 13 dBm Livello di ingresso per 7 5 kHz di deviazione 20 dB SCA2 8 11 8 13 dBm MPX 10 12 13 13 dBm Livello di ingresso per 75 kHz di deviazione 0 dB Left 37 36 13 13 dBm Right 15 32 13 13 dBm When setting input sensitivity please consider that the default menu report...

Page 26: ...ar briefly on the display quickly followed by modulation and forward power readings provided that the transmitter is delivering output power Menu 1 1b In case of a password has been set through the Miscellaneous menu enter the code and then confirm to be able to view or modify the parameters of the machine The screen that is shown is similar to the following Menu 2 NOTE It is advisable to write do...

Page 27: ...as output is enabled from menu 4 or in the event the machine is already set to ON and energised 1d If the equipment is not used for some time it will enter in STAND BY mode where the screen will remain backlit and indications on time and date will be indicated on the display Menu 0 Press press any button to exit from this screen 2 Ensure that machine is not in a locked out state Press the ESC key ...

Page 28: ...ettings are output power set to upper limit unless otherwise specified by customer and OFF 5 3 Management Firmware The machine features an LCD with two lines by 16 characters that displays a set of menus Figure 5 2 below provides an overview of machine menus The symbols listed below appear in the left portion of the display as appropriate Cursor Highlights selected i e accessible menu Filled arrow...

Page 29: ...d Menu Menu 9 Channels Menu Menu 0 Standby Menu Menu 10 Clock Menu Figure 5 2 When the display is off touching any key will turn on backlighting When the display is on pressing the ESC button from the default menu menu 1 calls up the selection screen menu 3 which gives access to all other menus Menu 4 If the temperature alarm is enabled and the alarm threshold is exceeded the following screen will...

Page 30: ...r and press the ENTER button To return to the default menu menu 1 simply press ESC again 5 3 1 Operation Menu Fnc In this menu you can toggle transmitter power output On Off set deviation display mode and the threshold rate for Forward PgD or Reflected PgR Power Good To edit an item highlight the appropriate line using the and buttons and then press and hold the ENTER button until the command is a...

Page 31: ...wer control and reporting When output power drops below set Power Good threshold the equipment changes the state of pin 7 of the DB15 Remote connector located on the rear panel PgR Modifies Power Good threshold for reflected power The Power Good rate is a percent of equipment rated power 350W for TEX3500LCD not of reflected output power This means that this threshold set at 4 respectively will giv...

Page 32: ... of forward power to amplifier module power in percent FWD PWR Vpa x Ipa Tmp Equipment internal temperature reading 5 3 4 Setup Menu Set This menu lets you view and set operating frequency The FSK function generates periodic carrier frequency shifts to generate a Morse coded station ID code NOTE This function is typically used in the USA The factory setting for frequency shift amplitude is 10KHz a...

Page 33: ...his procedure requires 1 RS232 male female cable Hyper Terminal interface make sure it has been installed together with Windows or equivalent serial communication software A brief description of the procedure is provided below Connect the PC serial port COM to the SERVICE connector on the rear panel of TEX3500LCD using a standard Male DB9 Female DB9 serial cable Power on the transmitter Launch the...

Page 34: ...et to 0000 by default this configuration automatically disables the entry of the password in default screen NOTE It is advisable to write down the password set if you forget the password it is not possible to recover it automatically To recover the password contact Customer Service by sending the alphanumeric PUK code of 6 characters generated automatically when entering the password 5 3 6 Channel...

Page 35: ... hours minutes and seconds of the equipment HH mm ss Dat Adjustment of the date of the equipment dd MM yy DoW Adjustment of the name of the day of the week Mon1 Adjusting the first Monday event in which occurs the power variation set in percentage Mon2 Adjusting the second Monday event in which occurs the power variation set in percentage Tue1 Adjusting the first Tuesday event in which occurs the ...

Page 36: ...in which occurs the power variation set in percentage Sat1 Adjusting the first Saturday event in which occurs the power variation set in percentage Sat2 Adjusting the second Saturday event in which occurs the power variation set in percentage Sun1 Adjusting the first Sunday event in which occurs the power variation set in percentage Sun2 Adjusting the second Sunday event in which occurs the power ...

Page 37: ...4 USer Manual Rev 2 0 27 01 20 Menu 10 Note that these are readings rather than settings and cannot be edited note the empty arrow Rel Firmware release information Dat Release date Tab Shows table loaded in the memory ...

Page 38: ... as to make maintenance and any required module replacement easier 6 1 1 TEX3500LCD Upper view The figure below shows the equipment upper view with the various components pointed out Figure 6 1 1 DB15 flat filter card 2 Bias card 3 LPF card 4 Panel card 5 Service voltages generation 6 Main board 7 FAN1 8 FAN2 9 Driver card Temperature Measure Board 10 Splitter card 11 RF modules 12 Fuse card 13 Co...

Page 39: ...ply interface card 6 Power supplies modules 6 2 Spare parts The list below identifies the spare parts codes for a simple replacement of modules in case of maintenance Spare Parts Name Spare Parts Code Fans VTL9GL1224J RF pallet SP FIN249A Audio main card PLL VCO SP MBD175A CPU panel Display SP PAN240A Switching power supply KPSL4248 Interface card SP INT240A Surge protection block SP SRG249A Bias ...

Page 40: ...rams are included in the Technical Schedule Vol 2 7 1 Power supply The TEX3500LCD power supply can be divided into two basic sections Services and Power Supply which provide adequate power to the RF power amplifier modules The unit has a rectifier PFC able to ensure a cos φ of 0 998 and a switching power supplies that allow an efficiency of 90 7 2 Interface board This board performs the following ...

Page 41: ...input section The audio input section accommodates the circuitry that performs the following tasks Input impedance selection 15 kHz filtering for R and L channels Stereophonic coding Preemphasis Mono MPX and SCA channel mixing Clipper limits modulating signal level so that frequency deviation never exceeds 75kHz Modulating signal measurement 7 4 2 PLL VCO section This section of the board generate...

Page 42: ...keep unbalance and power dissipation to a minimum The whole RF section is mounted on a finned heat sink with fan cooling 7 7 LPF Board This board incorporates a low pass filter to keep amplifier harmonics within permissible limits as specified by international standards A directional coupler is provided at filter output to measure forward and reflected RF output power power readings are relayed to...

Page 43: ...ng AGC Abnormal conditions affecting bias voltage so as to trigger foldback current limiting are Reflected output power too high External AGC signals Ext AGC FWD Ext AGC RFL Temperature too high Current draw of one RF module too high 7 9 External Telemetry Interface Board This board provides an I O interface for the CPU with the outside environment All available equipment input and output signals ...

Page 44: ...e restarting the equipment Be sure to disconnect the amplifier s mains supply before proceeding to any maintenance operation on the system 8 3 Ordinary maintenance The only regular maintenance required on the TEX3500LCD is the periodic blower replacement and dust cleaning of the air filter and of any trace of it inside the amplifier The frequency of these operations depends on the operating condit...

Page 45: ...Rev 2 0 27 01 20 Unscrew all the points A with the help of an Phillips screwdriver A Unscrew laterally all the points B with the help of an Phillips screwdriver B Unscrew all the points C with the help of an Phillips screwdriver C ...

Page 46: ...n order to reassemble and fix the blower in place Replace the covers and tighten all the screws necessary to close it 8 4 Module substitutions Only authorized and qualified technical personnel must be proceed with the replacement of the component parts in the relevant device 8 4 1 How to replace the power supply Open the bottom cover of TEX3500LCD by unscrewing all the screws Identify the power su...

Page 47: ...500LCD 41 54 USer Manual Rev 2 0 27 01 20 Unscrew all the points A with the help of an Phillips screwdriver A Extract the metal plates B B Unscrew all the points C with the help of an slotted screwdriver C ...

Page 48: ... replace it with a new spare part Redo all previously steps performed in reverse in order to reassemble and fix the module in place Replace the cover and tighten all the screws necessary to close it 8 4 2 How to replace the RF module Open the top cover of TEX3500LCD by unscrewing all the screws Identify the RF module to be replaced through a visual inspection a voltage check and or the verificatio...

Page 49: ...nectors A and unsolder the points B B A Unscrew all the points C with the help of an Allen screwdriver C At this point replace the module placing a bit of composite paste with high thermal conductivity and without silicones on the back of the new RF module We recommend the composite paste of HTC Electrolube or equivalent ...

Page 50: ... to the indicated value reading However if the ammeter does not provided any information it is very probable that the fuse is broken Proceed with its replacement following the next chapter D E Redo all previously steps performed in reverse in order to reassemble and fix the module in place Replace the cover and tighten all the screws necessary to close it 8 4 3 How to replace the fuses Open the to...

Page 51: ...Redo all previously steps performed in reverse in order to reassemble and fix the module in place Replace the cover and tighten all the screws necessary to close it 8 4 4 How to replace power supply interface board Open the bottom cover of TEX3500LCD by unscrewing all the screws Identify the module to be replaced Disconnect the connector A and faston B ...

Page 52: ...ly interface board and replace it with a new spare part Redo all previously steps performed in reverse in order to reassemble and fix the module in place Replace the cover and tighten all the screws necessary to close it 8 4 5 How to replace the main board Open the top cover of TEX3500LCD by unscrewing all the screws Identify the module to be replaced Unscrew the seven screws A on the rear panel o...

Page 53: ...r box B Disconnect the connector C and unscrew the RF connector D D C Remove the main board and replace it with a new spare part Redo all previously steps performed in reverse in order to reassemble and fix the module in place Replace the cover and tighten all the screws necessary to close it ...

Page 54: ...the connectors B B Remove the panel group and replace it with a new spare part Redo all previously steps performed in reverse in order to reassemble and fix the module in place Replace the cover and tighten all the screws necessary to close it 8 4 6 How to replace the driver card Open the top cover of TEX3500LCD by unscrewing all the screws Identify the module to be replaced Disconnect the connect...

Page 55: ...assemble and fix the module in place Replace the cover and tighten all the screws necessary to close it 8 4 7 How to replace the telemetry card Open the bottom cover of TEX3500LCD by unscrewing all the screws Identify the module to be replaced Unscrew the hexagonal washerA and the two threaded hex spacers B on the back panel of the TEX3500LCD A B Disconnect the connector C ...

Page 56: ...20 TEX3500LCD C Remove the card and replace it with a new spare part Redo all previously steps performed in reverse in order to reassemble and fix the module in place Replace the cover and tighten all the screws necessary to close it ...

Page 57: ... the variants compared to the basic version to be requested in the order For more information about the options rely on the respective user manuals 9 1 AUDIGIN TEX option Digital Input Left MONO Right Type TOS LINK Female Type XLR Female 1 GND 2 Positive 3 Negative 9 2 RDS TEX3HE option ...

Page 58: ...v 2 0 27 01 20 TEX3500LCD Service RDS Type DB9 Female 1 GND 2 RS232 TX 3 RS232 RX 4 NC 5 GND 6 NC 7 NC 8 RDS CARRIER OUT 9 PILOT IN 9 3 TLW TEX E 3HE option Ethernet Type RJ45 Female 1 TX 2 TX 3 RX 4 NC 5 NC 6 RX 7 NC 8 NC ...

Page 59: ...DB9 Female Type DB9 Female 1 NC 1 NC 2 TX_D 2 NC 3 RX_D 3 NC 4 Internally connected with 6 4 NC 5 GND 5 GND 6 Internally connected with 4 6 12 V 7 Internally connected with 8 7 NC 8 Internally connected with 7 8 NC 9 NC 9 NC Ethernet Type RJ45 Female 1 TX 2 TX 3 RX 4 NC 5 NC 6 RX 7 NC 8 NC ...

Page 60: ...or RF output power level to allow for UP DOWN setting The UP or DOWN command is provided by switching the corresponding signal at the connector to ground for at least 500mS pin features internal pull up to power supply Configuration of DB15F telemetry connector Remote Pin Standard Function UP DOWN Power Function 14 On cmd Up cmd Enables the RF power supply Increases the RF power supply 15 Off cmd ...

Page 61: ..._____________________________________________________________ ______________________________________________________________________________ ______________________________________________________________________________ ______________________________________________________________________________ ______________________________________________________________________________ ______________________...

Page 62: ...06 Fax 39 051 6011104 e mail info rvr it web http www rvr it The RVR Logo and others referenced RVR products and services are trademarks of RVR Elettronica in Italy other countries or both RVR 1998 all rights reserved All other trademarks trade names or logos used are property of their respective owners ...

Reviews: