Operating frequency setup. Set a new frequency value and then
press the
ENTER
button to confirm your selection; the transmitter
unlocks from current frequency (the
LOCK
LED turns off) and will
lock to the new operating frequency (
LOCK
turns back on again).
If you press
ESC
or let the preset time time out, the previous frequency
setting is retained.
FSK
Enables / disables FSK code transmission.
Cod
Regolazione del codice Morse inviato normalmente. Il codice viene
considerato solamente se completo di 6 caratteri (alfanumerico e senza
spazi).
5.3.4.1 Changing the ID code
User may change the FSK code used as a station identifier at any time.
This procedure requires:
• 1 RS232 male-female cable;
• Hyper Terminal interface (make sure it has been installed together with
Windows®) or equivalent serial communication software
A brief description of the procedure is provided below:
• Connect the PC serial port COM to the SERVICE connector on the rear panel
of
TEX3500LCD
using a standard Male DB9 - Female DB9 serial cable.
• Power on the transmitter;
• Launch the serial communication software;
• Set communication parameters as follows:
Baud Rate:
19200
Data Bit:
8
Parity:
None
Stop Bit:
1
Flow control:
None;
• Activate Caps-Lock through the communication software and send string CODE
followed by the 6-character station ID code followed by Enter.
NOTE: To be treated as valid, the code must be made up of 6 alphanumeric
characters and must contain no blank spaces; if acknowledged as valid, code is
echoed back to the terminal, illegal codes are not echoed.