TEX1000-LCD
18 / 38
User Manual
Rev. 1.1 - 23/06/05
[26] FWD EXT. AGC
Trimmer for the control of the delivered power in function of the
FWD fold input (REMOTE connector).
[27] RFL EXT. AGC
Trimmer for the control of the delivered power in function of the
RFL fold input (REMOTE connector).
[28] I
2
C BUS
DB9 connector for I
2
C bus networking.
[29] REMOTE
DB15 connector for telemetry of the machine.
[30] LEFT-MONO/MPX ADJ
Adjustment trimmer for Left-Mono channel input .
[31] SERVICE VOLTAGE SEL. Mains voltage selector 120-240V.
[32] SERVICE FUSE
Service protection fuse.
[33] LEFT-MONO/MPX
XLR connector, Left-Mono channel input
[34] FUSE 2
Mains supply fuse.