User Manual
Rev. 1.0 - 05/04/13
• Power supply connection by means of cable coming out of the PS module
ending with the ILME CXM 4/2 type of socket (DC Output). Only for
PJ5000U-
K
there are two outgoing cables, from PS module, to connect.
Figure 5-1
Example of PJ5000U-K installation in a rack
Connect the output of a suitable type of FM exciter (e.g. the PTXLCD of R.V.R.
Elettronica) to the RF input (
RF
module) using a cable fitted with N type connectors.
The exciter should be set to minimum output power and OFF.
Connect the amplifier’s INTERLOCK connector (on the back of the
PS
module)
to the exciter’s Interlock input, if available (it is available in all RVR Elettronica
exciters) using a twin wire with BNC connectors.
Note:
he amplifier’s INTERLOCK connector is an output. The operating logic is
as follows: the internal conductor floats when the amplifier works correctly, on the
contrary power is delivered and the internal conductor is closed to ground to halt
the exciter.