COLD
COLD
1
2
3
4
1 Connecting tank
Place the tank in position and connect
the inlet hose to the inlet combination
valve using the large fibre washer sup-
plied. Connect the tap hose to the fit-
ting at the top of the tank using the
small fibre washer and size 10 and 14
spanners.
2 Electrical
connection
Connect the tap by plugging the LED
cable into the hole provided at the
back of the tank cover. Plug the tank
into the socket. Switch the socket on
but not the tank yet.
3 Filling tank
Open the boiling-water handle of the
tap and the stop valve on the inlet
combination valve. Check for leaks.
Flush the tank through until the water
is clear. Black water will flow out
initially. This is Norit carbon from the
filter and completely harmless.
4 Switching on
tank
Switch on the tank. After the water
has heated up, the entire content of
the Quooker must be flushed out
once before use.
E
10
14
Connecting tank
• The Quooker tank is supplied with a UK 3 pin plug and requires a standard
13 amp earthed socket.
• If the mains lead is damaged it should be replaced by the manufacturer, their
agent or a qualified technician to prevent hazard.
• The light ring on the Nordic single tap, the Fusion or Flex tap will light up to
indicate when the water is being heated inside the tank.
• The Q-shaped button on top of the tank is the on/off switch. Once the water
is up to temperature the light on the tank will fade in and out.
• Ensure that the tank has sufficient height clearance to avoid pinching the hose.
• Do not use any washers or sealants other than the ones supplied.
Installatieinstr VAQ E UK 30.225.03.V15 11-12-18 09:32 Pagina 18