Section VI - Compressor Fluids
Sampling Procedures
Preferred sample location is the fl uid fi lter. If unable to take sample from fl uid fi lter, proceed as
follows:
1. Shutdown and lockout compressor.
2. Relieve pressure in reservoir.
3. Remove plug from reservoir drain line.
4. Drain water from reservoir and discard in approved manner.
5. Fill sample bottle with fl uid.
6. Close valve and replace plug in drain line.
7. Return compressor to service and check fl uid level during operation. Service with fl uid as
required.
Using fl uid fi lter sample valve, proceed as follows:
1. Open valve, drain 2-4 ounces of fl uid from fi lter and discard in an approved manner.
2. Fill sample bottle.
3. Close valve.
After collecting sample from either of the above methods:
1. Fill out information label completely.*
Be certain to provide all information as to possible hazards related to a given sample. If this situation
exists, all information shall be clearly marked on the sample bottle label.
2. Attach Sample Bottle Label to the bottle and put bottle in mailer.
3. Place Shipping Label on the outside of the mailer and send it by UPS.
FROM: ________________________________________
Customer Fax # ___________________________________
Model No._____________ Serial No. _________________
Fluid __________________ Sample Date_______________
Hours on Fluid _________ Hours on Machine __________
Distributor________________________________________
Sample From
Reservoir
Filter
Sample Bottle Label
Shipping Label
Note: A fl uid sample valve kit is available from Quincy Compressor. Contact the Service
Department and ask for part number 143286.
FROM:
TO:
Quincy Compressor Fluid Analysis
2300 James Savage Road
Midland, MI 48642-6535
55
Summary of Contents for QSI-90
Page 2: ......
Page 70: ...Appendix A Dimensional Drawings QSI 90 120 140 micro 66...
Page 71: ...Appendix A Dimensional Drawings QSI 90 120 140 micro dry 67...
Page 72: ...Appendix A Dimensional Drawings QSI 90 120 140 micro tank mounted 68...
Page 73: ...Appendix A Dimensional Drawings QSI 90 120 140 micro dry tank mounted 69...
Page 74: ...Appendix A Dimensional Drawings QSI 90 120 140 guage 70...
Page 75: ...Appendix A Dimensional Drawings QSI 90 120 140 guage dry 71...
Page 76: ...Appendix A Dimensional Drawings QSI 90 120 140 guage tank mounted 72...
Page 77: ...Appendix A Dimensional Drawings QSI 90 120 140 guage dry tank mounted 73...
Page 78: ...Appendix A Dimensional Drawings QGV 20 25 30 460V 74...
Page 79: ...Appendix A Dimensional Drawings QGV 20 25 30 460V dry 75...
Page 80: ...Appendix A Dimensional Drawings QGV 20 25 30 460V tank mounted 76...
Page 81: ...Appendix A Dimensional Drawings QGV 20 25 30 460V dry tank mounted 77...
Page 91: ......