Section III - Installation
Relief Valves
Pressure relief valves are sized
to protect the system. Never
change the pressure setting or
tamper with the valve. Only
the relief valve manufacturer
or an approved representative
is qualifi ed to make such a
change.
DANGER!
Relief valves are to protect system
integrity in accordance with ANSI/
ASME B19 safety standards. Failure
to provide properly sized relief valves
could result in death or serious injury.
Electrical
Before installation, the electrical supply
should be checked for adequate wire size
and capacity. During installation, a suitable
fused disconnect switch or circuit breaker
should be provided. Any unreasonable
voltage unbalance (5%) between the legs
must be eliminated and any low voltage
corrected to prevent excessive current
draw. The installation, electric motor,
wiring and all electrical controls must
be in accordance with National Electric
Code, and all state and local codes. A
qualifi ed electrician should perform all
electrical work.
Air compressors must be
grounded in accordance with applicable
codes.
See control panel for the proper
wiring diagram.
Quincy would like to emphasize the
importance of providing adequate
grounding for air compressors. The
common practice of grounding units to
building structural steel may not actually
provide adequate grounding protection, as
paint and corrosion buildup may exist.
CAUTION!
NEMA electrical enclosures and
components must be appropriate to
the area in which they are installed.
Relief valves are to be placed ahead of
any potential blockage point that includes,
but is not limited to, such components
as shutoff valves, heat exchangers and
discharge silencers. Ideally, the relief
valve should be threaded directly into the
pressure point it is sensing, not connected
with tubing or pipe and pointed away from
any personnel. Always direct discharge
from relief valves to a safe area away from
personnel.
13
Summary of Contents for QSI-90
Page 2: ......
Page 70: ...Appendix A Dimensional Drawings QSI 90 120 140 micro 66...
Page 71: ...Appendix A Dimensional Drawings QSI 90 120 140 micro dry 67...
Page 72: ...Appendix A Dimensional Drawings QSI 90 120 140 micro tank mounted 68...
Page 73: ...Appendix A Dimensional Drawings QSI 90 120 140 micro dry tank mounted 69...
Page 74: ...Appendix A Dimensional Drawings QSI 90 120 140 guage 70...
Page 75: ...Appendix A Dimensional Drawings QSI 90 120 140 guage dry 71...
Page 76: ...Appendix A Dimensional Drawings QSI 90 120 140 guage tank mounted 72...
Page 77: ...Appendix A Dimensional Drawings QSI 90 120 140 guage dry tank mounted 73...
Page 78: ...Appendix A Dimensional Drawings QGV 20 25 30 460V 74...
Page 79: ...Appendix A Dimensional Drawings QGV 20 25 30 460V dry 75...
Page 80: ...Appendix A Dimensional Drawings QGV 20 25 30 460V tank mounted 76...
Page 81: ...Appendix A Dimensional Drawings QGV 20 25 30 460V dry tank mounted 77...
Page 91: ......