Trouble
Probable Cause
Intercooler pressure
•Compressor valves or valve unloaders in first stage not functioning
abnormally low
properly or defective
(Two stage models only)
•Restricted air inlet filter or suction line
•Pilot valve or pressure switch set incor rectly or defective
•Pressurized air at valve unloader not vent ing properly when demand for
air is re quired; vent passage at hydraulic unloader or threeway valve
could be plugged
•Compressor valve or head gasket leaking
•Worn piston rings
•Defective pressure gauge
•Leaking air at intercooler or intercooler connections
Compressor overheats
•Clogged intake system
•Defective compressor valves
•Pressure setting too high
•Clogged intercooler, internally or exter nally
•Inadequate ventilation, or recirculation of hot air
•Pulley/sheave rotation wrong
•Incorrect speed
•Running clearances insufficient
(piston to cylinder wall or running gear)
•Lubrication inadequate
•Compressor incorrectly sized
High discharge
•Compressor valve assemblies defective
temperature
•Discharge pressure too high
•Inadequate ventilation or hot air recirculat ing
•Cooling surfaces of compressor or inter cooler excessively dirty
•Internal surface of heat exchanger fouled
•Ambient temperature too high
•Scored or excessively worn cylinder walls
Compressor knocks
•Head clearance insufficient
•Piston loose in cylinder bore, cylinder bore worn, piston or piston rings
worn
•Worn rods or main bearing
•Wrong pressure setting, discharge pressure excessive
•Crankcase lubrication inadequate
•Loose pulley/sheave
•Compressor valve assemblies loose