QR-25 Series
Quincy Compressor
52201-107, December 2012
29
3501 Wismann Lane, Quincy IL - 62305-3116
PILOT VALVE ADJUSTMENTS
All adjustments made to the pilot valve must be performed by a qualified technician. The adjustments must
be made while the unit is operating, therefore, extreme caution must be taken while working on the unit.
Observe all necessary precautions. Always use a backup wrench and make all differential and unload pres
sure adjustments in very small increments (1/8 turn).
WARNING !
The pressure switch and / or pilot valve are set at the factory for maximum efficiency. Adjustments to either com-
ponent must be performed by a qualified technician. Exceeding the factory recommended maximum pressure
will void the warranty and may cause personal injury.
*
Setting Unload Pressure
*
Step 1. Flip the toggle to
the “RUN” position
as shown, or turn
the knurled knob (if
so equipped) coun
terclockwise until it
stops.
Step 2. Loosen locknut (coun
terclockwise). * Sta-
bilize with back-
up wrench!
Step 3. Turn clockwise to increase unload pres
sure, turn counterclockwise to decrease
unload pressure. Hold position with
wrench and proceed to Step 4.
Step 4. Tighten locknut (clockwise) with wrench.
* Stabilize with back-up wrench!
Setting Differential Pressure
Step 5. Loosen locknut (counterclock
wise). * Stabilize with back-up
wrench!
Step 6. Turn clockwise to decrease
the differential pressure and
counterclockwise to increase
the differential pressure. Hold
position with wrench and pro
ceed to Step 7.
Step 7. Tighten locknut (clockwise)
with wrench. * Stabilize with
back-up wrench!
“MANUAL
UNLOAD”
position
(Ref.)
Summary of Contents for QR-25 210
Page 42: ......