6
Maintenance
6.1
Maintenance instructions
Important
The dryers contain refrigerant HFC.
When the automatic operation LED is lit, starting and stopping of the dryer are controlled
automatically.
If the dryer start/stop timer is active, the dryer may start automatically, even if it was
stopped manually.
Safety precautions
When handling refrigerant R410A, all applicable safety precautions must be observed. The
following points are stressed:
• Contact of refrigerant with the skin will cause freezing. Special gloves must be worn and, if
there is contact with the skin, the skin should be rinsed with water. On no account may
clothing be removed.
• Fluid refrigerant will also cause freezing of the eyes; therefore, safety glasses must be worn.
• Refrigerant R410a is poisonous. Do not inhale refrigerant vapors. Check that the working
area is adequately ventilated.
When removing the side panels of the dryer, be aware that internal elements such as the pipes
can reach a temperature of 120 ˚C (248 ˚F). Therefore, wait until the dryer has cooled down
before removing the side panels.
Before starting any maintenance or repairs, switch off the voltage. Isolate the dryer from the air
net and depressurize by opening valve (5) on inlet collector (6).
Valve on the inlet collector (Air-cooled)
Instruction book
102
2920 1992 00
Summary of Contents for QED-1250
Page 2: ......
Page 6: ...8 2 AIR DRYER DATA 108 9 Pressure equipment directives 112 Instruction book 4 2920 1992 00 ...
Page 15: ...Position of components Air cooled dryer Water cooled dryer Instruction book 2920 1992 00 13 ...
Page 17: ...Connections Rear view of Air cooled dryer Instruction book 2920 1992 00 15 ...
Page 31: ...Electrical diagram air cooled QED 1800 ES870 Instruction book 2920 1992 00 29 ...
Page 32: ...Electrical diagram air cooled QED 2100 ES1010 Instruction book 30 2920 1992 00 ...
Page 36: ...Electric cubicle air cooled QED 2100 ES1010 380 V and 460 V Instruction book 34 2920 1992 00 ...
Page 86: ...Dimension drawing air cooled QED 1600 ES760 Instruction book 84 2920 1992 00 ...
Page 87: ...Dimension drawing air cooled QED 1800 ES870 Instruction book 2920 1992 00 85 ...
Page 88: ...Dimension drawing air cooled QED 2100 ES1010 Instruction book 86 2920 1992 00 ...
Page 89: ...Dimension drawing water cooled QED 1250 ES610 Instruction book 2920 1992 00 87 ...
Page 90: ...Dimension drawing water cooled QED 1600 ES760 Instruction book 88 2920 1992 00 ...
Page 91: ...Dimension drawing water cooled QED 1800 ES870 Instruction book 2920 1992 00 89 ...
Page 95: ...Installation proposal water cooled dryer Instruction book 2920 1992 00 93 ...
Page 115: ......
Page 116: ...No 2920 1992 00 2021 05 ...