Section VIII - Technical data
49
Installation method C according table
B.52.1.
Single-core or multi-core cable on a
wooden wall.
Maximum allowed current in function of the ambient temperature for installation method
C.
Cable
section mm
2
Ambient temperature
30°C
40°C
45°C
50°C
55°C
4
< 32 A
< 28 A
< 25 A
< 23 A
< 20 A
6
< 41 A
< 36 A
< 32 A
< 29 A
< 25 A
10
< 57 A
< 50 A
< 45 A
< 40 A
< 35 A
16
< 76 A
< 66 A
< 60 A
< 54 A
< 46 A
25
< 96 A
< 84 A
< 76 A
< 68 A
< 59 A
35
< 119 A
< 104 A
< 94 A
< 84 A
< 73 A
50
< 144 A
< 125 A
< 114 A
< 102 A
< 88 A
70
< 184 A
< 160 A
< 145 A
< 131 A
< 112 A
95
< 223 A
< 194 A
< 176 A
< 158 A
< 136 A
120
< 259 A
< 225 A
< 205 A
< 184 A
< 158 A
Installation method F according table
B.52.1.
Single-core cables, touching in free air
Clearance to wall not less than one
cable diameter.
Maximum allowed current in function of the ambient temperature for installation
method F.
Summary of Contents for QCV 045
Page 2: ...This page intentionally left blank...
Page 21: ...Section III Installation 21 Dimension drawing QCV 045 QCV 90 vacuum pump...
Page 22: ...Section III Installation 22 Dimension drawing QCV 220 vacuum pump...
Page 23: ...Section III Installation 23 Dimension drawing QCLP 90 Overpressure pumps...
Page 24: ...Section III Installation 24 Dimension drawing QCLP 220 Overpressure pump...
Page 55: ...Notes 55...