Section VI - Operating instruction
34
drive motor is indicated by an arrow shown on the motor fan cowl. If the rotation
direction of the drive motor is incorrect, open the isolating switch and reverse two
incoming electric lines. Incorrect rotation direction of the drive motor may cause
damage to the pump.
Start and run the pump for a few minutes. Check that the pump operates normally.
Open the inlet isolation valve.
Reinstall the canopy panel(s).
If you intend to apply the pump on humid applications, it is
recommended that the unit is allowed to achieve optimal running
temperature before it effectively put in operation. This can be done
by running the unit against a closed suction line for 30 minutes.
Starting
Procedure
Check oil level and oil condition.
Switch on the voltage.
To avoid excessive energy consumption and damage to the
pump, the maximum allowed starting frequency is 30 starts per
hour.
During operation
Regularly check the oil level and the oil condition. The oil level should be in the middle
of the oil sight glass. Top up, if necessary, with correct type of oil.
It is recommended to use genuine lubricants.