USE & OPERATION (CONTINUED)
FILLING WITH WATER & ICE (COOL MODE)
Remove the power adapter and cord from the unit and the electrical outlet before emptying or
refilling the water tank. Wait for 2 minutes before removing the Water Tank to allow any excess water
in the Honeycomb Cooling Media to drip into the tank before removing it.
Note:
After removing the tank, water from the Honeycomb may continue to drip and collect in the
tank compartment. Simply wipe dry with a clean, dry cloth.
CAUTION:
WATER FILTER*
Some models are equipped with a water filter in the tank, which helps to
filter dust, hair and other particles from entering the water tank. Simply pour
water over the filter when refilling the tank.
To clean the water filter, simply push the bottom of the filter cup upwards to
release from the filter frame. Remove dust and hair from the filter sponge and
rinse under clean water. When clean, replace the sponge and secure the
filter cup back into the frame.
AUTO-OFF SAFETY SYSTEM
This unit is equipped with an Auto-Off Safety System. When the water tank is detached from the
unit or if the tank is incorrectly positioned, the unit will turn off automatically. To restart the unit, the
tank must be attached to the unit correctly.
Ice Compartment
Filter Cup
*Applicable for models with water filter feature only.
Water
Filter
Slide out the Water Tank. Refill the tank when water level is low. Do not fill
water above the "Max." water level mark to avoid water droplets collecting
on the louvers. Check the water level in the tank before running the Cool
Mode function. The Low Water Alarm will sound when water is low. Running
the unit in Cool Mode with inadequate water may cause pump failure.
If ice is available, you may add ice in the top ice compartment to
enhance the cooling performance.
Note:
The water capacity refers to the total volume of water that can be
contained within the air cooler water tank and water distribution system.
The water capacity in the tank at the “Max.” indicator level may be lower
than the actual water capacity of the air cooler.
WARNING:
Do not fill water tank with dirty water or salt water. This can damage the unit and
Honeycomb media.