MANUAL FOR SLIDING DOOR CONTROL UNIT
General description:
Ÿ
Power supply: 24 VAC - 6A
Ÿ
Back-up battery: 12V 2A Pb with integrated charger and functional test every 12 hours
Ÿ
Output: 28 VDC +/- 15% with 500 mA fuse
Ÿ
Encoder input (direction and pulse) with cable test
Ÿ
Motor speed control with PWM signal
Ÿ
Output for electromagnetic door lock with PWM signal
Ÿ
User-programmable operating parameters
Ÿ
Non-volatile (flash) data storage that does not require back-up power
Ÿ
Open/close cycle meter with 2 selectable maintenance alarm settings
Ÿ
Audible alarms for alerts
Ÿ
Seven-section digit for operation messages
Ÿ
Normally open auxiliary contact for doors in motion (optional)
Parameter Programming
Entering User-programmable parameters
If the PIN code has been entered correctly, the display will read ‘
1
’ to indicate the first
user-adjustable setting.
To change the value of the setting, select the desired parameter by pressing ‘
INVIO
’. The
parameter number will increase by 1 each time the key is pressed, and when the desired
parameter is reached use the UP and DOWN keys to change its setting.The display will flash
when the setting can be changed.
To move to another parameter, press INVIO until the desired parameter is reached and use the
UP and DOWN keys to set the desired value.
The settings will be saved automatically a few seconds after no further keys are pressed, or can
be saved immediately by pressing the INVIO button until the last parameter is reached and then
one further time to confirm the values.
The new settings are confirmed with the message ‘
rd
’ on the display and a 1 second tone.
Figure 1 contains a list of all user-programmable parameters.
Unit setup
After installation, the control unit will automatically measure the size of the door system; if the
system is connected correctly, a few seconds after providing power the setup program will start.
The door will slide slowly to position itself first at the mechanical stop for the open position and
then at the mechanical stop for the closed position.
If the entire procedure is completed successfully the line on the screen will flash, while if errors
were encountered the screen will display the error message . (
List of messages viewable on the
screen
)
The setup program can be activated at any time using the ‘RESET’ feature (see input selector).
Caution without power supply, also with battery inserted, the control board do not enter in setup
mode.
Note: during the setup program the radar proximity sensors are disabled, so to prevent
injury please ensure that no people or animals approach the doors during this process.
The botton test it is able to do the test directly on the control board.