Fig. 20
* NA = Normally open NC = Normally closed
SIGNAL
TYPE* DESCRIPTION
FUNCTION
COM
Common electrical signal.
SAFE CLOSE
NC
Signal for the connection of an external
photocell or safety control device for
wing closing
If the door is closing and the contact opens, the unit sends and immedi-
ate motion inversion command. Closing will only recommence after the
contact closes.
The signal must be short circuited with COM if not devices (internal
or external) are connected.
AUX IN
NA
Auxiliary input signal. Auxiliary devices
can be connected to this signal. It is nor-
mally used for inter lock functions.
When used as an auxiliary signal the function logic can be person-
alised according to customer requests.
When used as inter lock logic, closing this signal inhibits door func-
tions that will not open even with open signal presence.
AUX OUT
Auxiliary output signal, PNP transistor
type for particular door condition signals
(reset, open, closed, etc).
According to the type chosen signal, the output becomes active
(12Vdc and led on) when the door is in the set condition (Reset,
open, closed, etc).
SAFE OPEN NA
Signal for the connection of sensors for protec-
tion during wing opening.
If the door is opening and the contact closes, the unit sends an immedi-
ate movement stop command. Opening will only continue after this sig-
nal is deactivated.
KEY
NC
Lock signal. Closure devices can be con-
nected such as electronic key, key selec-
tor, transponder, etc.
The signal can be controlled in bi or
mono-stabile mode with an activation
time equal to about 500 msec.
If the signal opens the unit sends a complete wing closure command
(from any position) From this moment until the signal is closed the
door stays in this position and no external peripheral is detected
(including multi-logic selectors). As soon as the signal closes the door
opens permitting access.
The signal must be short circuited with COM if no devices are
connected.
START 1
NA
Opening signal. Wing opening devices
can be connected.
Closing this signals causes the wings to open. This signal is only moni-
tored in 2 Radar logic.
START 2
NA
Opening signal. Wing opening devices
can be connected.
Closing this signals causes the Door to open. This signal is monitored in
both 2 Radar and 1 Radar logic.
14