Electric Lock (12V 6W) Operation Selection
S5 ON
First input mode
Mono-stable
S5 OFF (DEFAULT)
First input mode
Bi-stable
First Input Mode Selection
SWINGY can be connected to a closing device such as an electronic key, key selector, transponder, etc.
Using the dip switch S5, the signal can be controlled in bistable or monostable mode with an activation time of about 500msec.
t
0
1
Stop
Normal
Closing device
readings
Automatism
Operation
t
0
1
Stop
Normal
Closing device
readings
Automatism
Operation
Antipanic mode Selection
S6 ON
Antipanic mode active.
In the event of power failure, the
equipment moves the doors to the
“Stop open” position, and stays in
this condition until power returns or
a new logic is selected using the
multi-logic selector.
S6 OFF (DEFAULT)
Antipanic mode disabled.
In the event of power failure the
equipment continues working
powered by the battery.
Logic right / left opening sense
S8 ON
Wing Left Opening rigid pull arm
Wing Right Opening articulated
push arm
S8 OFF (DEFAULT)
Wing Right Opening rigid pull arm
Wing Left Opening articulated
push arm
Wing Left Opening rigid
pull arm
Wing Right Opening
articulated push arm
Wing Right Opening
rigid pull arm
Wing Left Opening
arti
culated push arm
QKSW80
12
S7 ON
Electric Lock active.
The electrick lock is excited for a few moments
few millimetres before opening to allow the release
As per default setting, the impulse timing of the
electric lock is 120ms.
S7 OFF (DEFAULT)
Electrick Lock
disabled
Electric lock must be 12V 6W max.
whilst the door is opening, the door reverses a
the electric lock. Whilst the door is closing, it acce-
lerates and then undergoes a thrust during the last
few millimetres to rearm the lock.