background image

Manufacturer:

   QUIKO ITALY

Address:

VIA SECCALEGNO 19  

36040 SOSSANO (VI)

Declares that the product SWINGY

Is built to be incorporated in a machine or to be assem-

bled with other machinery to build a machine considered

Therefore it is not fully compliant to the dispositions of

this  Directive  since  it  is  not  yet  assembled  with  other

components. 

It  is  in  conformity  to  the  following  other  CE  directives:

2004/108/EC  Electro-magnetic  compatibility  and  further

used until the machine it is incorporated in or is a com-

Directive  2006/42/EC  conditions  and  national  legislation

declared.

Sossano

, 10/11/2011

by Directive  2006/42/EC

    

3

Installation Instruction

Thank you for choosing this product. For best automatism

performance, Quiko recommends you carefully read and

follow the installation and use instructions found in this man-

ual. Installation of this automatism must only be performed

ual  is  addressed.  Any  errors  during  installation  may  be

harmful to people or things. P ackaging material (wood, plas-

tic, cardboard, etc.) should not be scattered in the environ-

ment or left within the reach of children as potential sources

of  danger .  Every  installation  phase  must  be  performed  in

accordance with the regulations in force and following Good

Technique  standards.  Before  beginning  installation  make

sure that the product is integral and has not been damaged

during transportation or by poor storage conditions. Before

installing the product make sure that each architectural and

structural element of the entrance (girder fastening surfaces,

be  automated.  Conduct  a  careful  risk  analysis  and  make

cutting  and  hazardous  areas  in  general.  Do  not  install  the

fumes  are  present.  The  manufacturer  is  not  liable  for  any

construction of the casing to be motorised and any collapse

of  the  same.  All  automatic  entrance  safety  and  protection

devices (photocells, active sensors, etc.) must be installed

in  accordance  with  the  regulations  and  directives  in  force,

forces and inertia in play. Pay careful attention to area where

the following may occur: crushing, cutting, conveyance and

any  other  type  of  hazard  in  general  applying,  if  necessary

tion  information  on  every  installation.  Make  sure  that  the

upstream  electrical  system  is  correctly  dimensioned  and

has  all  the  opportune  protections  (circuit  breakers  and

fuses).  Only  use  original  spare  parts  in  maintenance  and

repairs.  Do  not  tamper  or  alter  devices  in  the  automatism

and all the safety devices in the control panel for any reason.

The manufacturer is not liable if parts within the automatism

are altered or tampered with or if safety devices other than

those indicated by the manufacturer are used in the system.

The  automatism  installer  must  provide  the  automatic

entrance manager with the use manual and all the informa-

tion  required  for  correct  use  in  automatic  and  manual

modes  (even  for  electronic  locking)  and  in  the  event  of

emergency. 

Pay careful attention to the messages in this manual that are

marked with the hazard symbol. They can either be warn-

ings aimed at avoided potential equipment damage or spe-

This device was designed to automate swinging doors.  Any

other use is considered contrary to the use foreseen by the

manufacturer who therefore shall not be held liable.

Machine directive

The installer who motorised a door becomes the automatic

door machine manufacturer according to directive 2006/42/EC

and must:

Arrange the Technical Booklet with the documents indi-

cated in attachment V of the Machine Directive and keep

them for at least 10 years. 

Draft  the  CE  declaration  of  conformity  according  to

attachment II-A of the machine directive and provide the

use with a copy.

Apply the CE markings on the motorised door according

to point 1.7.3 of attachment I of the machine directive.

QKSW80

Summary of Contents for Swingy QK-SW80

Page 1: ... QK SW80 USER MANUAL V01_2011 ...

Page 2: ...pag 11 Double wing Master Slave selection pag 11 Low Power mode selection pag 11 First input mode selection pag 12 Antipanic mode selection pag 12 Electric Lock selection pag 12 Logic right left opening sense pag 12 Type of arm selection pag 13 SWINGY electronic board pag 13 Connections pag 13 Led functions pag 15 Jumpers pag 15 Start up Operating logic pag 16 Error Message Table pag 17 Double SWI...

Page 3: ...ame All automatic entrance safety and protection devices photocells active sensors etc must be installed in accordance with the regulations and directives in force forces and inertia in play Pay careful attention to area where the following may occur crushing cutting conveyance and any other type of hazard in general applying if necessary tion information on every installation Make sure that the u...

Page 4: ...up of A Steel fastening base B Plastic cover C Gear motor unit D Electronic control panel E Transformer F Emergency battery 12V 1 3Ah G Encoder unit H Switch Installation Instruction 4 Fig 1 Fig 2 Power supply 230V ac 50 Hz Nominal power 60 W Nominal motor torque 35 Nm External device power 12Vdc 2 5W Emergency battery 12 V 1 3 Ah Max opening angle 100 Wing maximum weight 80 Kg Wing dimensions 700...

Page 5: ...with the product to make easier the installation Fig 4 440 311 65 87 47 9 153 269 76 94 9 Dimension of the fixing holes and cables opening SWINGY standard In case of double SWINGY provide to the predisposition of the connection cables passing between the two operators QK SW80 ...

Page 6: ...wings anticlockwise direc tion the assembly of the automatism perfectly mir rors the left hand opening assembly Rigid pull arm Aluminium guide Gearmotor Axis OPENING DIRECTION Fig 6 WARNING The final tighte ning of the screws must be perfor med only after having checked that the vertical positioning of the automatism guarantees a good parallelism between the hinge axis and the gearmotor axis For t...

Page 7: ...nsions articulated push arm QK SW80PUSH The articulated push arm is used when the automatism is installed on the approach side of the door the side opposite the swing side WARNING For a correct positioning always use the main axis of the wing hinges and the operation axis of the gear motor as a reference as shown in Fig 7 WARNING The final tightening of the screws must be performed only after havi...

Page 8: ...on ding to the V impression on the guide profile Use the holes to fix the guide to the frame using the appropriate screws Fig 11 Part C Insert the cylindrical slide Fig 11 Part D complete with the relative spindle inside the guide and distribute a uniform layer of grease over the sliding zone Then after finishing the installation of the rigid arm Fig 11 Part E screw the threaded shaft inserted in ...

Page 9: ...es Insert the bracket of the arm Fig 13 part A in the appropriate seat on the gearmotor and fix it using the two countersunk head screws provi ded Carefully check that the upper part of the articulated arm rotates easily under the frame of the wing Fig 7 8 and 9 Drill the frame at the positions indicated in Fig 7 and fix the wing attach ment of the articulated arm to the frame using the appropriat...

Page 10: ...st or shavings Ensure the proper fixing of the automatism on the wall Check correct tightening Check that the wires are fixed and that no wire pass near the carriage sliding area Check that the arm is solidly fixed to the wing and that it is equipped with the appropriate stop to limit the max opening angle to 100 Electrical connections WARNING All board or peripheral connections on the terminal bo...

Page 11: ...al mode S1 ON S2 ON S3 ON Enter double Master door If asynchronous it is the first to open and the last to close S1 OFF S2 ON S3 ON Enter double Slave door If asynchronous it is the last to open and the first to close Synchronised door motion Asynchronous door motion A single selector can be connected and extended to several SWINGY automatisms using two different operation logics DEFAULT the selec...

Page 12: ...or S6 OFF DEFAULT Antipanic mode disabled In the event of power failure the equipment continues working powered by the battery Logic right left opening sense S8 ON Wing Left Opening rigid pull arm Wing Right Opening articulated push arm S8 OFF DEFAULT Wing Right Opening rigid pull arm Wing Left Opening articulated push arm Wing Left Opening rigid pull arm Wing Right Opening articulated push arm Wi...

Page 13: ... led D33 is on it indicates normal voltage presence 12V If off check For mains and or battery voltage BASE SELECTOR Shielded cable with 4 wires 0 22 mm Do not con nect the shield of the wire used Fig 19 Type of arm selection J13 ON ARTICULATED PUSH ARM Wing Left Opening or Wing Right Opening J13 OFF DEFAULT RIGID PULL ARM Wing Left Opening or Wing Right Opening In order to optimize the operation o...

Page 14: ...n the set condition Reset open closed etc SAFE OPEN NA Signal for the connection of sensors for protec tion during wing opening If the door is opening and the contact closes the unit sends an immedi ate movement stop command Opening will only continue after this sig nal is deactivated KEY NC Lock signal Closure devices can be con nected such as electronic key key selec tor transponder etc The sign...

Page 15: ...ripheral power supply Fig 22 Diagnostics Led see Error Message Table External peripheral signal presence led LED Functions Jumpers Jumper ON OFF Default J13 Articulated arm Rigid pull arm J11 Set cycle operations Normal operation J12 Set properly the jumper J13 look at the arm typology paragraph QK SW80 ...

Page 16: ...ons without connections to the open command device use the START button on the unit see Fig 17 Standard manoeuvre The device opens and closes the door accelerating and decelerating in accordance with the opening and closing speed limits which will be reached at low speed Push Go An initial push on a closed door will cause it to open Reverse function radar 1 and 2 If the radar detects an obstacle w...

Page 17: ...se it again at normal speed After detecting the third obstacle without being able to complete the manoeuvre without completely opening the door the device signals a malfunction AV intermittent and L1 On stops for a few seconds whilst closing and then performs a new reset to set the ends of stroke If the object remains in the movement area it will be detected as the end of stroke and the device wil...

Page 18: ...same way as with single devices If it is detected that one of the devices is trying to open a door this will cause both doors to open The anti crush safety devices and obstacle detection functions are controlled separately and independently by both cards If one card detects an anti crush device whilst closing it will stop the motion of both doors and open them completely at low speed If one card d...

Page 19: ... QK SW80 ...

Page 20: ...Quiko Italy Sas Via Seccalegno 19 36040 Sossano VI Italy Tel 39 0444 785513 Fax 39 0444 782371 info quiko biz www quikoitaly com ...