Overview
6
1.3. Weighing view
In the
Weighing view
you can perform load weighing. To be able to enter the
Weighing view
, the selected implement has to be
calibrated for load weighing, see
2.2.6. Calibrate load weighing
, as well as having its level position set, see
.
The weight of the load is estimated by continuously measuring the hydraulic pressure in the cylinders while inside the
weighing range during a lift cycle.
Each weighing calibration consists of two reference lifts, one with a known reference weight and the other with the implement
empty. By using two lifts, the weight can be estimated by interpolating between the two reference lifts.
00:56:34
79000
13
51625
kg
1575
Auto
magnus
14:56
bucket / gravel
0
31
17
16
15
1
2
3
4
5
6
7
8
9
10
11
12
13
14
Fig.3 Load weighing view
1.
Setpoints
10.
Number of added lifts
2.
Weighing range (grey filled)
11.
Target weight
3.
Loader height (0-100%)
12.
Select weighing mode
4.
Implement angle
13.
Sum
5.
Implement angle deviation
14.
Activity recording
6.
Activity timer
15.
Tare indicator
7.
Weighing mode indicator
16.
Weight
8.
Home screen
17.
Lower loader indication
9.
Setup weighing