MAINTENANCE
The control panel needs no particular maintenance. To ensure optimum performance from the equipment, once a year check the
cables and the electrical connections.
Clean the control panel with a soft cloth dampened with water. Do not use chemical or abrasive products to clean the control
panel.
SYSTEM PROBLEMS - MAINTENANCE - TECHNICAL DATA
The resetting of this class of problems occurs, once the cause that has generated them has been removed, by switching off and
switching back on the remote control.
When problems 3, 4, 5 are present, it may be necessary to turn off and turn back on the external devices that signalled the pro-
blem. Refer to their installation and use manual.
N. OF
FLASHES
PROBLEM
DESCRIPTION
1
Overload on the
command electrical
line
The problem is signalled when the control detects a short circuit or an overload on the command
electrical line of the propeller. Check the wiring of the electrical line of the remote control to
the propeller and the absorption of the remote control switches installed on the propeller.
2
Interruption on the
command electrical
line
The problem is signalled when the control detects an interruption on the command electrical
line of the propeller.
Check the wiring of the electrical line of the remote control to the propeller.
3
Problem present on
the BTR* propeller.
The control system of the BTR propeller has detected a problem.
Refer to the BTR use and maintenance manual.
4
Problem present in the
parallel/series switch*
The control system of the PSS switch has detected a problem. Refer to the PSS use and
maintenance manual.
5
Problem present on
TMS*
The TMS line switch has detected a problem connected to the remote control switch of the
propeller. Refer to the TMS use and maintenance manual.
* If installed.
(1) With power supply voltage less than 8 Vdc the control panel can reset.
(2) Typical value with control panel disabled.
(3) Typical value with control panel enabled and one direction button pressed.
(4) Excluding the back of the control panel (IP20).
TECHNICAL DATA
MODEL
TCD 1022
TCD 1042
OUTPUT CHARACTERISTICS
Current capacity of right or left thruster
commands.
4A max
INPUT CHARACTERISTICS
Supply voltage (1)
from 8 to 31 Vdc
Quiescent current (2)
10 mA
Maximum current absorption (3)
55 mA + absorption of remote control coil
AMBIENT CHARACTERISTICS
Operating temperature
from -20 to +70 °C
Protection rating (4)
IP 66
GENERAL CHARACTERISTICS
Dimensions including frame (L x L)
78 mm x 78 mm
78 mm x 78 mm
Weight
80 g
140 g
EMC class
EN 60945 - FCC TITLE 47 Part 15 SUBPART B CLASS B