18
ID
FAQ
Answer
7
What happens
if the Host
drops from the
network and
comes back
online?.
Nothing within 30min. After 30 min, push
RF button twice, and then push/hold RF
button for approx 4 seconds. Unit is reset.
Push RF button twice to reopen network and
rejoin. See section 7.3. (assuming Peer 1 unit
1 took over). The ex-Host unit can be joined
to the network as Peer unit, network issue
clears.
8
How can a unit
be added to the
network?
Push RF button twice on any existing
networked unit. Power on new unit and wait
for it to join. Push any RF button twice to
close network. See Section 7.2.
9
Can the joining
process be
reset/
restarted?
Yes. Push RF button twice to open network.
Press & hold the RF button until it flashes four
times. Press the RF button twice to re-open
its wireless network. See Section 7.3 for
details.
10
Is there a way
to get more
information
about a trouble
status?
In fault mode press RF button for Amber LED
error code. Count the number of Amber LED
flashes and report to customer support.
11
What happens if
the user created
more than one
Coordinator?
Only one Host is allowed per network.
See Section 7.3 to reset the extra Host;
for reconnection as a Peer unit.
12
How do I check
the number of
wireless units
in the network?
While in join mode, press and release RF
button on any joined unit. Amber LED will
blink out number of units.
13
Is it possible to
check if a unit is
the Host or an
Peer
Press the RF button twice quickly to place the
unit into Join Mode.
If the unit flashes twice every two seconds, it
is a Host. And if it flashes three times every
two seconds, it is a Peer device.
14
If the mains
power to the
smoke alarm is
turned off, will
the RF remain
on?
Yes, the RF wireless will remain on as it is
powered by the smoke alarm backup battery.
8. Wireless FAQs