Smart LTE Module Series
SC600Y&SC600T Hardware Design
SC600Y&SC600T_Hardware_Design 45 / 128
DC_IN
C1
C2
MIC29502WU
U1
IN
OUT
E
N
G
N
D
A
D
J
2
4
1
3
5
VBAT
100nF
C3
470uF
C4
100nF
R2
100K
47K
R3
470uF
470R
51K
R4
R1
1%
1%
Figure 5: Reference Circuit of Power Supply
1. It is recommended to switch off the power supply for module in abnormal state, and then switch on
the power to restart the module.
2. The module supports battery charging function by default. If the above power supply design is
adopted, please make sure the charging function is disabled by software, or connect VBAT to
Schottky diode in series to avoid the reverse current to the power supply chip.
3. When the battery power is reduced to 0%, the system will trigger automatic shutdown, so the design
of power supply should be consistent with the configuration of fuel gauge driver.
3.5. Turn on and off Scenarios
3.5.1. Turn on Module Using the PWRKEY
The module can be turned on by driving PWRKEY pin to a low level for at least 1.6s. PWRKEY pin is
pulled to 1.8V internally. It is recommended to use an open drain/collector driver to control the PWRKEY.
A simple reference circuit is illustrated in the following figure.
NOTES