background image

NOTE: the delay time may be prolonged for more then 10s of the time set by the parameter. 

 

Size: 2 Byte, Default Value: 0

Setting

Description

0

External IR relay/ External relay will not turn back on

30 - 32535

Seconds

Technical Data

Dimensions

53,6 x 84 x 65 mm

Weight

221 gr

Hardware Platform

ZM5101

EAN

3830062070683

IP Class

IP 20

Voltage

3x 230 V/400V

Load

65 A

Device Type

Smart Meter

Firmware Version

01.00

Z-Wave Version

04.3d

Z-Wave Product Id

0x0159.0x0007.0x0054

Supported Command Classes

Basic

Switch Binary

Meter

Crc 16 Encap

Association Grp Info

Device Reset Locally

Zwaveplus Info

Multi Channel

Supervision

Configuration

Manufacturer Specific

Powerlevel

Firmware Update Md

Association

Version

Multi Channel Association

Security

Transport Service

Security 2

Controlled Command Classes

Transport Service

Summary of Contents for GOAEZMNHXD1

Page 1: ...ication it will communicate with other devices secure as long as this device provides the same or a higher level of security Otherwise it will automatically turn into a lower level of security to main...

Page 2: ...properly from this network Reset to factory default This device also allows to be reset without any involvement of a Z Wave controller This procedure should only be used when the primary controller i...

Page 3: ...re info please see Qubino catalogue Product ordering codes model numbers IKA232 20 230V 030 046 833 000 BICOM432 40 WM1 30 074 038 Inclusion Exclusion On factory default the device does not belong to...

Page 4: ...your life more comfortable We have prepared a few of them for you so you can get an idea for your next smart home project Of course there are countless of other options for how to use Qubino 3 Phase S...

Page 5: ...des Description 1 1 Lifeline Configuration Parameters Z Wave products are supposed to work out of the box after inclusion however certain configuration can adapt the function better to user needs or u...

Page 6: ...l BLINK Size 1 Byte Default Value 0 Setting Description 0 External IR relay disabled 1 External IR relay enabled and connected to all 3 Phases 2 External IR relay enabled and connected to a Phase 1 Pa...

Page 7: ...070683 IP Class IP 20 Voltage 3x 230 V 400V Load 65 A Device Type Smart Meter Firmware Version 01 00 Z Wave Version 04 3d Z Wave Product Id 0x0159 0x0007 0x0054 Supported Command Classes Basic Switch...

Page 8: ...ave devices into a network Exclusion is the process of removing Z Wave devices from the network Association is a control relationship between a controlling device and a controlled device Wakeup Notifi...

Reviews: