49
Parameter no. 76 - Motor operation detection
Define the power consumption threshold at the end positions. Based on this value, the device
will know, that the shutters reached the limit switches.
Values (size is 1-byte dec):
•
default value 10 = 1 W
•
5 - 100 = 0,5 W
–
10 W.
NOTE: Motors with power consumption less than 0.5 W could not be auto-calibrated. In that
case set time manually with Parameter no. 74
Parameter no. 78 - Forced Shutter calibration
By changing the value of this parameter from 0 to 1, the Shutter enters the calibration mode. For
further information about the calibration process, please see section 9.
Values (size is 1-byte dec):
•
default value 0
•
1 - Start the calibration process. When the calibration process finishes
(completing the full cycle - up, down and up again), set the value of the parameter
78 (Forced Shutter calibration) back to 0.