EN
.
47
Parameter no. 73
–
Slats position
This parameter is used to enable/disable the slats to return to the previously set position after
being activated via the Z-Wave gateway(hub), push-button operation or when the lower limit
switch is reached.
Values (size is 1-byte dec):
•
default value 1
•
0 - disable
•
1 - enable
Parameter no. 74
–
Motor moving up/down time
This parameter defines the time, required by the Shutter motor, to completely open or
completely close the attached shutters.
Values (size is 2-byte dec):
•
default value 0
•
0
–
moving time disabled (working with limit switches)
•
1 - 32767 = 0.1seconds
–
3276.7 seconds
After the set time passes, the motor stops (relay goes to the off state).
NOTE: It is important that the reference position, for setting the moving time, is always when the
Shutter is at its lowest position!
Set parameter 74 to 0 and move the Shutter (using the up/down push-buttons or the main
gateway (hub) UI) to the lowest desired position. When the Shutter reaches this position, set the
parameter 74 to the duration, required by the Shutter, to completely open or completely close
Summary of Contents for FLUSH SHUTTER DC
Page 3: ...EN 3 18 Warning 58 19 Regulations 58...
Page 16: ...EN 16 4 Package Contents Flush Shutter DC Device Installation Manual...
Page 23: ...EN 23 After Qubino installation...
Page 29: ...EN 29 Step 2 Turn the fuse OFF Step 3 Connect the temperature sensor as shown below...
Page 30: ...EN 30 Step 4 Place the temperature sensor in the switch box Step 5 Turn the fuse ON...
Page 31: ...EN 31 Step 6 Re include the device to your network...
Page 32: ...EN 32 Step 7 Start using the temperature sensor in connection with your device...