Description

This device is used to arm, disarm, and separate the zones of the system by placing a 
transponder badge (item 3530S and item 3540 previously stored in the central unit) in 
front of the zone transponder badge receiver. 
When used in an automation system it performs the control function for the management 
of scenarios. 
By pressing one of the pushbuttons, the corresponding zone is armed/disarmed.
Within four seconds from the last pressure, the separation performed must be confirmed 
by moving a transponder saved in the central unit close to the device. 

 

Should this not take place, then the previous condition is automatically restored. Red LEDs 

on indicate that the zones are active, whereas red LEDs off show that they are disarmed. 

Configuration

BURGLAR-ALARM mode:

Since this item belongs to the activator group, it needs to be set up with the number of 
the “group” assigned and the progressive number of the devices in the “group”. It can also 
be programmed to perform Automation functions (scenario management). 
See Automation “MY HOME” guide for details.

Z

This configurator assigns the number of the appropriate zone (from 1 to 8) in the “group” 
of devices (any free zone in the system). To configure it as belonging to the activator 
group, no configurator must be inserted.

This configurator assigns the progressive number within the group of activators. 
Configurator 1 identifies the first device, configurator 2 identifies the second, and so 
forth, up to a maximum of 9 activators (dividers, expanders or activators).

NOTE: If all 9 permitted devices have already been assigned to the activator group, 
it could be possible to assign to configurator Z (zone it belongs to) a value between 
1 and 9, taking into account the progressive number.

MOD

It assigns the modes of the audible signals (BEEP) and luminous signals (LED ON) 
provided by the divider when controlled by the transponder; it is used as a activators/
disconnector of the “Burglar-alarm” system.

Technical data

- Power supply from SCS BUS:  27 Vdc
- Max. absorption:  

15 mA

- Operating temperature:  

5 – 40°C

Legend

1 - 

Transponder badge receiver zone;

2 - 

LED and pushbutton for controlling of zone 2;

3 - 

LED and pushbutton for controlling of zone 4;

4 - 

Indication “System ON/OFF”;

5 - 

Alarm warning;

6 - 

LED and pushbutton for controlling of zone 3;

7 - 

LED and pushbutton for controlling of zone 1.

Dimensional data

Size: 2 modules

AUX

Position not configurable for the “Burglar-alarm” function; configure only if it is necessary 
to enable the device for Automation functions (management of the scenarios stored in 
the unit or scenario module).

Front view

Z
No.
MOD
AUX

Clamp for burglar 
alarm BUS

Rear view

Central unit 
used

Configurator 
value

LED ON

Enabling
BEEP

3486
3485/B
HD/HC/HS/L/N/
NT4601

none

YES

YES

1

NO

YES

2

YES

NO

3

NO

NO

L/N/NT4600/1 
A/AM5780/1

4

YES

YES

5

NO

YES

6

YES

NO

7

NO

NO

1-4 zone transponder 

divider

MQ00028-c-EN

24/04/2014