Q-Controller System Operation Manual
- 20 -
86550-001-000 Rev B
5.2.2
Display Options
. Click [Display Options] to configure the Q-Controller display
Setting
Description
Display Disabled
Channel:
When a remote module is connected and you may disable any
unused channels. If it’s “Checked”, the disabled channel will be
displayed in tab [Monitoring]. If it’s “Unchecked”, the disabled
channel will not appear in tab [Monitoring] screen.
Display Negative
Reading:
It only works on the digital sensors and Analog Inputs value.
If it’s “Unchecked”, all negative readings will be displayed as “0”
Display OFFLINE if AI
Input < 2.5mA:
The feature only works on the Analog Inputs value.
If it’s “Checked”, the AI channel will report “CH OFFLINE” when
the input signal is less than 2.5mA.
If it’s “Unchecked”, the reading will be zero or negative reading if
“Display Negative Reading” is “Checked”.
Display Alarm Screen
and Wait for ACK:
When any alarm or output status changed, a red color flash
screen will be displayed if it’s “Checked”, it can only be cancelled
by clicking the right button [Acknowledge] to acknowledge the
alarms. If it’s “Unchecked”, no flash screen is popped up.