6- FILTER SERVICE & REPLACEMENT
LED Diagnostic Table -
“Service Filter(s)” Alerts (iSeries Controls)
If “Service Filter(s)” alert is FLASHING SLOWLY some of the particulate filters are getting clogged and need to replaced.
If “Service Filter(s)” alert is ON SOLID replace the odor filter.
Filter Access
Access to the filters are through the side access door & the top cover.
Install filters in the following sequence:
1
st
filter to be lowered into the LASER BLUE GEL is the chemical filter. Part #: AG111 (OR AG094, AG099).
2
nd
filter to be lowered into place is the HEPA filter. Part #: F074 (OR F075)
3
rd
filter to be lowered into place is the Hi Cap Part # : F073 (OR F164)
4
th
filter to be installed through side access door it the bag filter. Part #: F128
The above instructions are for the most popular filter sequence. For all other filter sequences follow the filter order
on the inside of the access door. This filter sequence can be customized for your application.
Disposal of both odor and particulate filters is the responsibility of the end user. Please contact local authorities for proper
and legal disposal of spent filters.
Odor Filter Refilling
The odor filter does not have to be replaced. It can be refilled with new filtration media.
FOR SYSTEMS WITH iSERIES CONTROLS:
If t
he “Service Filters” LED does not go out on its own after changing the filters follow the reset procedure below.
Resetting
“Service Filter(s)” Alert
1- Ensure filter access door is closed
2- Plug power back to the unit
3- Press & hold SPEED UP & DN simultaneously until unit BEEPS
4- Hold for 10+ seconds, when panel is beeping continuously, release buttons
5- You are now i
n RESET MENU, in this condition, “System ON” Led is FLASHING QUICKLY
6- Press SPEED DN (2 Times) until
“Service Filter(s)”
LED is FLASHING
7- Press & HOLD POWER button while
“Service Filter(s)”
LED is FLASHING & unit is BEEPING continuously
8- Release, when LED stops FLASHING & stops BEEPING
See the following page for replacement filter part numbers and filter maintenance guide.
Filter Side
Access Door
Hi Cap
Filter
PN: F073
STAGE 2
Laser Blue
Gel
Anti Microbial Bag
Filter PN: F128
STAGE 1
Filter Top
Access Cover
Filter Access
Screws
HEPA Filter
PN: F074
STAGE 3
Odor Filter
PN: AG111
STAGE 4