9- SPECIFICATIONS 

Nominal Airflow (Single Motor) 

110 CFM 

Nominal Airflow (Double Motor) 

220 CFM 

Nominal Airflow (Brushless Motor) 

280 CFM 

Approximate Dimensions: 

47" (1194mm) High x 16" (406mm) Wide x 25" (635mm) Deep 

Brushless Models 41” (1042mm) High 

Voltage/Phase/Frequency, Current, Power  

Single Brush Type 115/1/60, 7 Amps, 825 Watts 

Single Brush Type 230/1/50, 4 amps, 750 Watts 

Double Brush Type 115/1/60, 12 Amps, 1650 Watts 

Double Brush Type 230/1/50, 8 amps, 1500 Watts (Operating at 60Hz) 

Brushless 115/1/60:  6.8 amps, 1100 Watts 

Brushless 230/1/50: 3.4 amps 1200 Watts (Operating at 60Hz) 

Approx. Weight: 

100lbs (45kg) w/o filters 

160lbs (73kg) with filters 

 

10- GENERAL REPLACMENT PARTS 

Qty 

Description 

Part 

Power Cord 120v 

E500 

Power Cord (Euro 230V) 

E130 

Remote Cable 

AE427 

Cover Gasket Roll (40') 

H431 

Front Cover Gasket Kit 

AR147 

11- WARRANTY  

QUATRO Air Technologies warrants its equipment to be free from defect in material and workmanship under normal use 
and service for a period of one year from date of shipment.  QUATRO's obligation under this warranty shall be limited to 
replacing any parts, thereof, which shall be demonstrated to have been defective.  This is expressly in lieu of all other 
warranties, express or implied, including the warranties of merchantability and fitness. 
QUATRO claims no warranty as to merchantability or as to the fitness of the merchandise for any particular use and shall 
not be liable for any loss or damage.  No person, firm or corporation is authorised to assume for QUATRO any other liability 
in connection with the sale of these goods.  Equipment, parts and material manufactured by others and incorporated in 
QUATRO's equipment are warranted by QUATRO only to the extent of the original manufacturer's liability to QUATRO Air 
Technologies Inc. 

 

Conditions and Limitations: 

This warranty does not cover

 abuse, misuse, maintenance negligence, improper assembly, acts of vandalism, acts of 

God, fear wear, modifications of the equipment or installation of a part not recommended by QUATRO Air Technologies, as 
well as operation of the equipment at voltages other than those specified by QUATRO Air Technologies Inc.

  

 

 

Warning: 
This is a class A product. In domestic environment, this product may cause radio interference in which case the user may be 
required to take adequate measures. 

 

 

 

 

 

For Technical Assistance, call QUATRO Air Technologies inc. at 

(514) 630-4444 (in Montreal, Canada). 

 

Please ensure that you have your 

equipment serial number

 available when calling.

 

Summary of Contents for CSA600 Series

Page 1: ...com info QUATRO air com CSA600 Series Premium Turbine Dust Collectors Instruction Maintenance Manual READ AND UNDERSTAND THIS MANUAL BEFORE OPERATING THE SYSTEM STORE THE MANUAL IN A SAFE PLACE FOR FU...

Page 2: ...xcessive moisture water or rain Use only on a grounded electrical circuit Do not install or operate the system in an enclosed space or against a wall Unit may overheat shut down Keep all objects at le...

Page 3: ...These alarms are accompanied by an audible alert See the table on the following page to understand the meanings of the LEDs and the alarms Alarms Status Conditions Alarm Mute Feature All alarms can b...

Page 4: ...nd Filter Cleaning Filter Service Replacement Instructions L3 Flashing Slowly Beep Every Hour Filter Pressure Near Critical Service Becoming Urgent Replace Filters Continued Operation May Result In Un...

Page 5: ...atus The Quatro System is designed to be used with other pieces of equipment that can support remote operation and or remote status monitoring The connection is made using the AE427 QUATRO Universal R...

Page 6: ...ely if the piece of equipment supports that function The piece of equipment must be set or programmed to shut itself off when the Quatro Run signal is OPENED Contact your equipment manufacturer to ver...

Page 7: ...omized for your application Disposal of both odor and particulate filters is the responsibility of the end user Please contact local authorities for proper and legal disposal of spent filters Odor Fil...

Page 8: ...3 Months Service Filters ON Service Filters Flashing 2 Hi Cap Every 6 Months None None 3 HEPA Every 6 18 Months Service Filters ON Service Filters Flashing 4 Odor Every 6 18 Months None Service Filter...

Page 9: ...s 5 You are now in RESET MENU in this condition System ON Led is FLASHING QUICKLY 6 Press SPEED DN 1 Time until Service Motor s LED is FLASHING 7 Press HOLD POWER button while Service Motor s LED is F...

Page 10: ...l be limited to replacing any parts thereof which shall be demonstrated to have been defective This is expressly in lieu of all other warranties express or implied including the warranties of merchant...