CONTENTS: 

 

 

INTRODUCTION  

 

 

Introduction to the product.  

 

4

 

 
 

PRODUCT IDENTIFICATION

 

 

Product Identification 

 

 

 

 

DELIVERY AND INSTALLATION

   

Receipt of Equipment. 

 

 

 

 

 

 

 

 

Off Loading 

 

 

 

 

  

EXTENDED STORAGE

 

 

 

Maintenance 

 

 

 

  

 

 

 

 

 

Internal Surfaces   

 

 

  

 

 

 

 

 

External Surfaces  

 

 

  

 

 

 

 

 

Static Indentation  

 

 

  

 

 

 

 

 

Filters 

 

 

 

 

 

 

 

INSTALLATION   

 

 

Dimensional details 

 

 

6

 

 

 

 

 

 

 

Pre Unit Installation 

 

 

7

 

 

 

 

 

 

 

Fitting unit 

 

 

 

 

 

 

 

 

 

Fitting float switch  

 

 

7-9 

 

 

 

 

 

 

Connection of ductwork 

 

 

 

 

 

COMMISIONING

  

 

 

Airside Measuring and Balancing 

 

10  

    

 

 

 

 

 

Electric Air Heaters 

 

 

10  

 

 

SERVICE AND MAINTENANCE

 

 

Warranty 

 

 

 

10 

   

 

 

 

 

 

Fans 

 

 

 

 

11 

   

 

 

 

 

 

Electric Heating Element   

 

11 

  

 

 

 

 

 

Controls  

 

 

 

12 

   

 

 

 

 

 

Condensate Tray  

 

 

12 

   

 

 

 

 

 

Coils 

 

 

 

 

12 

   

 

 

 

 

 

Filters 

 

 

 

 

13 

   

 

 

 

 

 

Insulation 

 

 

 

13 

   

 

 

 

 

 

Routine Maintenance Schedule  

 

13 

 

 

WIRING  

 

 

 

Controls General   

 

 

14

 

 
 

 

GENERAL INFORMATION 

 

Component Specification.   

 

14

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Summary of Contents for Amber Series

Page 1: ...Units Designed for Ceiling or Void Mounting INSTALLATION OPERATION MAINTENANCE INSTRUCTIONS TEV Ltd Armytage Road Brighouse West Yorkshire United Kingdom HD6 1QF UK Tel 01484 405630 Fax 01484 405620...

Page 2: ...e used 4 It is manually isolated from the electrical mains supply 5 Electrical equipment is earthed to comply with IEE regulations and local by laws 6 All electrical work must be carried out by a Qual...

Page 3: ...ntation 5 Filters 5 INSTALLATION Dimensional details 6 Pre Unit Installation 7 Fitting unit 7 Fitting float switch 7 9 Connection of ductwork 9 COMMISIONING Airside Measuring and Balancing 10 Electric...

Page 4: ...s AC Speed control of the fan motors is achieved by means of a multitapped auto transformer which is wired to a three speed and fine adjustment switches Supplied with continuous filament media filters...

Page 5: ...aged Maintenance It is essential that the following instructions as laid down in this section are carried out and maintained during the period of storage before commissioning Internal Surfaces If duct...

Page 6: ...B Spigot Options Weight approx Kg AMB 1 630 595 1 2 3 4 37 AMB 2 880 845 1 2 3 4 45 AMB 3 1230 1195 1 2 3 4 5 55 AMB 4 1230 1195 1 2 3 4 5 60 AMB 5 1430 1395 1 2 3 4 5 70 AMB 6 1430 1395 1 2 3 4 5 75...

Page 7: ...unit up using a spirit level checking to ensure the unit sits level in both directions the drip tray is designed with a built in fall to ensure condensation runs to the drain connection 7 Use nuts and...

Page 8: ...nt pipe is higher than the water level in the drip tray 13 The drain pipe from the condensate pump must be run to a common drain It is important that any condensate pump installed must be in accordanc...

Page 9: ...Typical installation showing ductwork connected to unit The ducts should be pushed fully over the spigot up to the outer casing of the unit and secured to the spigot with screws once fitted they shou...

Page 10: ...ation of the condensation pump by pouring a small amount of water into the drain tray and ensure the pump clears any water and operates any alarms etc 13 Start the fan and blow through the system thor...

Page 11: ...ice and maintenance of Quartz fan coil units and must be read before any maintenance is attempted WARNING It is essential that before any work is carried out the unit is isolated externally from the e...

Page 12: ...ws and slide element upwards letting the screw head pass through the key hole slots 5 Remove wires from element take note of terminal connections used 6 Remove elements from the unit must be replaced...

Page 13: ...irty filters will reduce the air volume handled by the unit thus adversely affecting its performance The length of time between cleaning of filters is dependant upon the environment A six to twelve mo...

Page 14: ...emperatures Alternatively Electric Heating elements are available and can be supplied wired for single phase or three phase supply as appropriate or as specified Multiple units fitted on the same syst...