background image

Sealant

or Caulk

INSTALLATION INSTRUCTIONS     

ATTIC PROTECTION

Quarrix.com  

 800.438.2920

8

1. Ridge Ventilation Slot Preparation

The  slot  must  be  cut  on  a  new  roof  before  field  tile  installation.  The 
amount  of  ventilation  is  controlled  by  the  length  of  slot  cut  along  the 
roof ridge. Remember, for the most attractive roofline, it is recommended 
that  Quarrix  ridge  vents  be  installed  along  the  entire  ridge  of  the 
roof.  For 

5

8

”  profile  vents,  a  3

1

2

”  slot  should  be  cut  (1

3

4

”  on  each  side  of 

ridge).  For  1”  profile  vents  a  4”  slot  should  be  cut  (2”  on  each  side  of  the 
ridge).  A  minimum  of  6”  must  be  left  uncut  on  each  end  of  the  ridge. 
Once  the  slot  is  cut  and  the  battens  are  installed,  it  is  time  to  install  the 
field  and  trim  tiles  per  the  tile  manufacturer’s  installation  instructions. 
After  field  tile  installation,  the  ridge  now  is  ready  for  vent  installation. 

2. End Cap Installation

Pull apart a precut section of the foam end cap found with the vent. Using a 
utility knife, make a cut in the StormStop material 

1

2

” on each side of the vent, 

back  from  the  end  of  the  section.  Using  construction  adhesive  or  sealant 
caulk, coat both sides of the StormStop material where it has been cut back 
at the end of the vent. Insert the foam end cap with the cut-back StormStop 
material between the foam end cap and the underside of the vent to assure a 
weather-tight seal. 

3. Vent Placement on Ridge

Before installing the vent on the ridge, a bead of sealant is required between 
the roof tile and the under side of the ridge vent. This sealant should fill any 
voids between the bottom of the vent and the surface of the tile. Caulking 
and sealants shall be suitable for exterior use and be resistant to weathering. 
The  caulking  and  the  sealants  shall  be  compatible  with  and  adhere  to 
the  materials  to  which  they  are  applied.  Check  sealant  manufacturer’s 
instructions for compatibility. Roll out or place vent along the entire length 
of  slot  also  covering  the  6”  minimum  uncut  ridge  on  both  ends.  Multiple 
lengths  of  vent  can  be  joined  by  butting  the  sections  tightly  together.  
An end cap should be inserted at the end of each section.

FlatTile

ROOFS

3

1

2

INST-SSRV01.0

2

.0

4.

21

         

Distributed by Best Materials® LLC

http://www.bestmaterials.com      |      1-800-474-757

0

[email protected]    |      

http://www.bestmaterials.com      |      1-800-474-7570

     [email protected]    |      http://www.bestmaterials.com      |      1-800-474-7570

http://www.bestmaterials.com      |      1-800-474-757

0

[email protected]    |      

http://www.bestmaterials.com      |      1-800-474-7570

      [email protected]    |      http://www.bestmaterials.com      |      1-800-474-7570

Summary of Contents for StormStop

Page 1: ...ications a 4 slot should be cut 2 on each side of ridge Aminimumof6 mustbeleftuncutoneachendof theridge Oncetheslotiscutandanyoverlapping shingles covering the ridge are trimmed and removed the ridge is ready for vent installation The amount of ventilation is controlled by the length of slot cut along the roof ridge For the most attractive roofline it is recommended that Quarrix StormStop Ridge Ve...

Page 2: ...the roof shingles before installing the vent on the ridge This sealant should fill any voids between the bottom of the vent and the surface of the shingle UseeitherbutylsealantconformingtoASTMC1085 latex sealant conforming to ASTM C834 silicone sealant complying with ASTM C920 or asphalt roofing cement complying with ASTM D4586 Roll out or place Quarrix Ridge Vent along the entire length of slot a...

Page 3: ... has been installed properly if the bottom of the vent is flat on the roof and the peak is slightly rounded Description consult oretimi linam Verehena non tam reste non tus is Quarrix com 800 438 2920 INSTALLATION INSTRUCTIONS ATTIC PROTECTION Using One Pass Installation secure cap shingles and vent at the same time Nail ridge caps with roofing nails in a common overlapping pattern Nails should pe...

Page 4: ... end of the section Using construction adhesive or sealant caulk coat both sides of the StormStop material where it has been cut back at the end of the vent Insert the foam end cap with the cut back StormStop material between the foam end cap and the underside of the vent to assure a weather tight seal Because of the popularity of dimensional roofing material such as 40 50 year and lifetime lamina...

Page 5: ...This createsthemostattractiveridgeandhipline Insertthefoamendcapunder the ridge vent where it is at full width Fasten vent for hip at point where it meets ridge Roll out or place the vent all of the way down the hip covering 2 pre laid cap shingles at the bottom of the hip Go back over hip vents and fasten at 4 intervals If the vent is not being run the entire length of the hip use the cap shingle...

Page 6: ...e foam end cap with the cut back StormStop material between the foam end cap and the underside of the vent to assure a weather tight seal 3 Vent Placement on Ridge Before installing the vent on the ridge a bead of sealant is required between the stone coated steel and the underside of the ridge vent This sealant should fill any voids between the bottom of the vent and the surface of the panel Caul...

Page 7: ...bottom of the vent is flat on the roof and the peak is slightly rounded Install hip ridge caps per manufacturer s installation guide Each hip ridge piece should clip together by inserting the return at the nose of each piece into the back clip which is located at the top of the hip ridge cap section Fasten cap to vent through thebackclipusing 8screws Fastenersshouldpenetratethroughthewood roof dec...

Page 8: ...e it has been cut back at the end of the vent Insert the foam end cap with the cut back StormStop material between the foam end cap and the underside of the vent to assure a weather tight seal 3 Vent Placement on Ridge Beforeinstallingtheventontheridge abeadofsealantisrequiredbetween the roof tile and the under side of the ridge vent This sealant should fill any voids between the bottom of the ven...

Page 9: ...anner meet the requirement for weather blocking according to Concrete and Clay Roof Tile Design Criteria Installation Manual for Moderate Climate Regions ICBO ER 6034P 4 FlatTile ROOFS INST SSRV01 02 04 21 Distributed by Best Materials LLC http www bestmaterials com 1 800 474 757 0 sales bestmaterials com http www bestmaterials com 1 800 474 757 0 sales bestmaterials com http www bestmaterials com...

Page 10: ...r An end cap should be inserted at the end of each section Note For Class A Installation Only For Class A Quarrix vent installation follow steps 1 2 3 as stated above Once the vent has been installed use a utility knife with a hook blade and remove the corrugated plastic center section of the vent Do this for the hip and ridge This modified installation meets the requirements for UL790 Class A sta...

Page 11: ...intain the pitch of the roof SHINGLE ROOFS Cedar Shake INST SSRV01 02 04 21 Distributed by Best Materials LLC http www bestmaterials com 1 800 474 757 0 sales bestmaterials com http www bestmaterials com 1 800 474 757 0 sales bestmaterials com http www bestmaterials com 1 800 474 7570 http www bestmaterials com 1 800 474 757 0 sales bestmaterials com http www bestmaterials com 1 800 474 757 0 sale...

Page 12: ...p material between the foam end cap and the underside of the vent to assure a weather tight seal 3 Vent Placement on Ridge Beforeinstallingtheridgevent abeadofsealantisrequiredbetweenthemetalorfoamclosureand theundersideofthevent fillinganyvoids Caulkingandsealantsshallbesuitableforexterioruseand beresistanttoweathering useeitherbutylorpolyurethanesealants Thecaulkingandthesealants shall be compat...

Page 13: ...e cap over Quarrix Ridge Vent according to metal manufacturer s installation instructions Metal Roofs INST SSRV01 02 04 21 Distributed by Best Materials LLC http www bestmaterials com 1 800 474 757 0 sales bestmaterials com http www bestmaterials com 1 800 474 757 0 sales bestmaterials com http www bestmaterials com 1 800 474 7570 http www bestmaterials com 1 800 474 757 0 sales bestmaterials com ...

Reviews: