HICs and base ports
Cable
Data rate and
protocol
Number
and type of
connectors
Connector
Type
Length
12 Gb/s SAS or
6 Gb/s SAS
4 or 2 HIC
ports
MiniSAS-HD
passive copper
1-5m
MiniSAS-HD
optical
5-100m
Fan-out cable type
#3
passive copper
2m
6 Gb/s SAS only
4 or 2 HIC
ports
Fan-out cable type
#2
passive copper
2m
16 Gb/s, 8 Gb/s, or 4
Gb/s Fibre Channel
4 or 2 HIC
optical ports
SFP+
OM2 SW optical
2,3,5,10,25
m
SFP+
OM3 SW optical
50-100m
2 base
optical ports
SFP+
OM2 SW optical
2,3,5,10,25
m
SFP+
OM3 SW optical
50-100m
SFP+
OS1 LW optical
50-300m
10 Gb/s iSCSI or
1 Gb/s iSCSI
4 HIC
optical ports
SFP+
OM2 optical
2,3,5,10,25
m
SFP+
OM3 optical
50-300m
Twin-Ax (DAC)
passive copper
2-7m
2 base
optical ports
SFP+
OM2 optical
2,3,5,10,25
m
Twin-Ax (DAC)
passive copper
2-7m
2 base RJ-45
ports
RJ-45
Cat6a passive copper
2-100m
2 HIC
optical ports
SFP+
OM2 optical
2,3,5,10,25
m
SFP+
OM3 optical
50-300m
Twin-Ax (DAC)
passive copper
2-7m
2 HIC RJ-45
ports
RJ-45
Shielded Cat6a
passive copper
2-100m
1 Gb/s iSCSI only
4 HIC
optical ports
RJ-45 with 1 Gb/s
SFP
Cat5 passive copper
2-100m
2 HIC
optical ports
RJ-45 with 1 Gb/s
SFP
Cat5 passive copper
2-70m
The following table shows host cabling configurations for the E2700 controller-drive tray.
Host cabling | 53
Summary of Contents for StorNext QD7000
Page 1: ...Hardware Cabling Guide StorNext QD7000 Firmware 8 40 xx xx 6 68683 01 Rev A...
Page 7: ...Preface Hardware Cabling Guide vii...
Page 10: ...E Series Hardware Cabling Guide December 2017 215 11792_B0 doccomments netapp com...
Page 11: ......
Page 90: ...One E5660 controller drive tray and one DE6600 drive tray Drive shelf or drive tray cabling 81...
Page 106: ...One E2760 controller drive tray and one drive tray Drive shelf or drive tray cabling 97...