Chapter 3: System Specifications
Library Connection Types and Speeds
56
Scalar i6000 Planning Guide
Library Connection Types and Speeds
lists the library connection types and speeds.
Table 6 Library Connection
Types and Speeds
KVA
0.82
0.81
0.8
0.8
0.57
0.46
0.38
0.34
KVAR (capacitive)
0.28
0.27
0.27
0.27
0.18
0.17
0.15
0.14
Power Factor
0.94
0.94
0.94
0.94
0.95
0.93
0.92
0.91
Crest Factor
1.68
1.69
1.7
1.7
1.69
1.61
1.56
1.58
Amps (RMS)
4.06
3.92
4.04
3.91
2.78
2.31
1.93
1.75
Amps (Peak)
7.227
7.244
7.078
7.122
7.045
4.422
3.975
2.787
230V / 50 Hz / 1 pH.
Connection
a
a.The DB-9 serial connection on the management control blade is not intended for customer use.
Connector
Speed
Fibre Channel drive (control path bridging; HP LTO-5
and LTO-6 only)
LC
8 Gbps
Fibre Channel on FC I/O Blade
LC
4 Gbps (7404)
Ethernet on management control blade (MCB 2.0)
RJ45
1 Gb
Summary of Contents for Scalar i6000
Page 1: ...Planning Guide Quantum Scalar i6000 Library 6 66882 07 Rev A...
Page 6: ...Contents vi Scalar i6000 Planning Guide...
Page 54: ...Chapter 2 Description Encryption and Key Management Solutions 48 Scalar i6000 Planning Guide...
Page 92: ...Chapter 4 Site Preparations Additional Comments 86 Scalar i6000 Planning Guide...