FastStor Rack Mount Installation Instructions
11
8.
Using a #1 philips screwdriver, install the philips, panhead screw (#7) through the keyhole shaped cutout inside FastStor #2
into the threaded rear mounting hole inside FastStor #1.
Note:
If the threaded mounting hole is missing inside FastStor #1, it is an early rack-ready model. Complete the steps detailed in
Appendix B: Rear Mounting Point for Early Model Rack-Ready FastStor
, then continue this procedure with step 9 on page 11.
9.
Using a T-8 Torx driver, remove the upper and lower button head screws located at the front right side of FastStor #2.
10.
If not already mounted, use a #1 philips screwdriver to install the left-hand mounting bracket (#16) to the left side of FastStor
#1 using two philips, panhead screws (#7). Be sure that the thumbscrews are positioned at the bottom.
Keyhole shaped
cutout
Keyhole shaped
cutout