Coherent Modulation Transmitter | IQTX
Quantifi Photonics Ltd.
Version
1.04
37
Reviewing modulator bias values vs time error history plots
To review modulator bias value vs. time error history plots, click the HISTORY tab.
The polarization (X or Y) and the modulator biases (All, I, Q, P) can be selected and filtered by clicking the
drop down lists above the plots area.
The plots can be zoomed to show a specific section of the analysis by clicking and dragging the desired
area with the cursor. To reset the zoom, click the Autoscale button or double-click on the plot area.
To download a plot as a PNG file, click the ‘Download plot as a png’ button.