UANTA COMPUTER INC.
Layer 2,3,IPv6+QoS Switch
_____________________________________________________________________________
Layer 2,3,IPv6+QoS Network Switch User Manual Version 0.1
Page: 963/970
11.2.7.5.2.
Configuring Interface’s PIM-DM Configuration Page
Selection Criteria
Slot/Port - Select the Slot and port for which data is to be displayed or configured. Slot 0 is
the base unit. You must have configured at least one router interface before configuring or
displaying data for a PIM-DM interface, otherwise an error message will be displayed.
Configurable Data
Interface Mode - Select enable or disable from the pulldown menu to set the
administrative status of PIM-DM for the selected interface. The default is disabled.
Hello Interval - Enter the number of seconds between PIM hello messages transmitted
from the selected interface. The default value is 30. Valid values are from (10 to 3600).
Command Buttons
Submit - Send the updated configuration to the router. Configuration changes take effect
immediately. These changes will not be retained across a power cycle unless a save is
performed.
11.2.7.5.3.
Viewing Interface’s PIM-DM Configuration Page
Selection Criteria
Slot/Port - Select the physical interface for which data is to be displayed. There must be
configured at least one router interface before displaying data for a PIM-DM interface,
otherwise a message will be displayed.
Non-Configurable Data
Interface Mode - Displays the administrative status of PIM-DM for the selected interface.
The default is disabled.