background image

G

Power on the NI ELVIS II using the power switch on the back 
of the unit. The 

READY 

and 

ACTIVE

 LEDs on the top NI ELVIS II 

panel should briefly light, and the 

READY 

LED stays on.

Slide the PCI 
connector at 
the back of 
the QNET 
board into  
the female 
connector on 
the NI ELVIS II.

Place the handle 
on the front of 
the QNET board 
over the bracket 
located on the 
front of the NI 
ELVIS II.

Using the screws and hex key provided, 
anchor the QNET board to the ELVIS II  
in the locations indicated.

Connect the NI ELVIS II 
power supply to the back 
panel of the NI ELVIS II.

Use the NI ELVIS II USB cable 
to connect the NI ELVIS II 
Unit to your computer. 

E

F

A

Ensure that the NI ELVIS II power switch is in 
the OFF position.

PC

C

B

D

H

Ensure that 
the +5V LED 
on the QNET 
board is lit.

Power on the QNET Physics and 
Dynamics board by turning the NI 
ELVIS II prototyping board power 
switch. The 

POWER

 LED next to 

the switch should light up.

I

Setup Hardware

STEP 4

To setup the complete QNET Physics and Dynamics, please read the following instructions carefully. For full details, see 
the QNET Physics and Dynamics User Manual.