Q24/Q48 Tape Library
Installation and Operations Manual
Error
Code
Description
User Action
Critical Component Status
8F
Cannot find slider block
within the expected
range
Run ‘Library Verify Test’,
after several occurrences
contact technical support
Media changer probably defective.
Elevator distribution board defect.
Cabling incorrect.
Check slider gears.
90
Cannot find elevator
block within the
expected range
Run ‘Library Verify Test’,
after several occurrences
contact technical support
Media changer probably defective.
Elevator distribution board defect.
Cabling incorrect.
Check elevator gears.
91
Cannot find rotation
block within the
expected range
Run ‘Library Verify Test’,
after several occurrences
contact technical support
Media changer probably defective.
Cabling incorrect.
Check rotation gears.
92
Cannot find sled block
within the expected
range
Run ‘Library Verify Test’,
after several occurrences
contact technical support
Media changer probably defective.
Cabling incorrect.
Check sled gears.
93
Gripper outside range,
Gripper has reached a
position beyond the
expected range
Run ‘Library Verify Test’,
after several occurrences
contact technical support
Media changer probably defective.
Elevator distribution board defect.
Cabling incorrect.
Check gripper gears.
94
Slider outside range,
Slider has reached a
position beyond the
expected range
Run ‘Library Verify Test’,
after several occurrences
contact technical support
Media changer probably defective.
Elevator distribution board defect.
Cabling incorrect.
Check slider gears.
95
Elevator outside range,
Elevator has reached a
position beyond the
expected range
Run ‘Library Verify Test’,
after several occurrences
contact technical support
Media changer probably defective.
Elevator distribution board defect.
Cabling incorrect.
Check elevator gears.
96
Rotation outside range,
Rotation has reached a
position beyond the
expected range
Run ‘Library Verify Test’,
after several occurrences
contact technical support
Media changer probably defective.
Cabling incorrect.
Check rotation gears.
97
Sled outside range,
Sled has reached a
position beyond the
expected range
Run ‘Library Verify Test’,
after several occurrences
contact technical support
Media changer probably defective.
Cabling incorrect.
Check sled gears.
98
Cartridge present
sensor not found
Run ‘Library Verify Test’,
after several occurrences
contact technical support
Media changer probably defective.
Media changer controller defect.
Cartridge present sensor defect
(mechanics, electronics).
Cabling incorrect.
© Copyright QUALSTAR 2015
76