SOFTPRO INSTALLATION GUIDE
©2020 Quality Water Treatment. All rights reserved.
16
.
STEP 6)
Add additional resin media, if required*.
(Applies only to 80k or larger, otherwise skip
to the next step.)
*If over an 80,000 or larger grain capacity
softener, then add the appropriate media/
resin that was supplied to the top of the
mineral tank.
NOTE:
Systems from 24,000 through 64,000
grain capacity are pre-loaded with the proper
amount of resin.
Only the 80,000 or larger
grain capacity water softener will come with
additional resin to load into the mineral tank.
a)
Cover the opening of the distributor riser
tube (located at the top of the mineral tank)
with a cap, plastic bag, or tape.
b)
Pour all the resin media that was provided
to you into the mineral tank.
c)
Uncover the distributor tube.
d)
Clean off the interior tank threads with
water to remove any resin.
STEP 7)
Attach the control valve to the mineral tank.
a)
Place the valve onto the top of the mineral
tank.
b)
Guide the bottom of the basket to insert the
distributor riser tube (“D-Tube” or Riser
Tube) that is located inside the tank.
c)
Carefully screw the control valve onto the
mineral tank. Hand tighten ONLY. (The “O”
ring of the control valve will seal the tank.)
WARNING:
Be careful not to cross-
thread the valve. The valve should
screw on easily. Hand tighten ONLY.
WARNING:
Be careful not to pinch or
wind the electrical cord in the threads/
valve and tank connection.