SPECIFICATIONS

Rated Line Pull (Single Line)

Gear Reduction Ratio

Motor (Series Wound)

Drum Size

Dyneema

®

Synthetic Winch Line

Winch Line Capacity

Overall Dimension

Net Weight

Mounting Bolt Pattern

9000 lbs (4090 kgs)

212:1

12 Volt / 4.8 Hp (3.6 Kw)

2.64” x 9” (67mm x 228mm)

3/8” x 85’

Minimum Break Force 17,000 lbs.

22.44” x 6.6” 11.22” (570mm x 168mm x 285mm)

63.5 lbs. (28.8 kgs)

10” x 4.5” (254mm x 114.3mm)

Q9000 Winch 

with Synthetic Winch Line

Rated Line Pull (Single Line)

Gear Reduction Ratio

Motor (Series Wound)

Drum Size

Dyneema

®

Synthetic Winch Line

Winch Line Capacity

Overall Dimension

Net Weight

Mounting Bolt Pattern

Q11000 Winch 

with Synthetic Winch Line

11000 lbs (5000 kgs)

295.75:1

12 Volt / 4.8 Hp (3.6 Kw)

2.64” x 9” (67mm x 228mm)

3/8” x 85’

Minimum Break Force 17,000 lbs.

22.44” x 6.6” 11.22” (570mm x 168mm x 285mm)

65.3 lbs. (29.6 kgs)

10” x 4.5” (254mm x 114.3mm)

QSERIES_92112_203X_INSTALL_Layout 1  9/25/12  11:23 AM  Page 8

09252012112529

Summary of Contents for 92122.203 series

Page 1: ...3X REQUIRED TOOLS SAFETY GLASSES GLOVES TORQUE WRENCH 10 MM SOCKET 10 MM WRENCH 13 MM WRENCH 14 MM WRENCH 4 MM HEX ALLEN KEY 5 MM HEX ALLEN KEY P2 PHILLIPS HEAD SCREW DRIVER READ ALL SAFETY MESSAGES A...

Page 2: ...elf recovery winch Individual safety messages and sections of this manual may be preceded by the safety alert symbol in triangle and one of three signal words a hazardous situation which if not avoide...

Page 3: ...Attach the solenoid pack to the side mount solenoid bracket using a flat washer split lock washer and nut for each of the four studs Tighten using a 10mm wrench Photo A Photo B Tighten both 6mm x 1mm...

Page 4: ...nch power cables MUST be PROPERLY placed to the OUTSIDE of the rear tie bar as shown Power cables MUST NOT come in contact with a rotating winch cable assembly or power cable insulation MAY be comprom...

Page 5: ...ten brass bolt onto terminal using a 14mm wrench DO NOT OVER TIGHTEN Fire Electrical Spark Chemical Burn Hazards Connecting winch to battery and winch operation may cause electrical arcs Never install...

Page 6: ...nt plate with the included 10mm nuts and bolts qty 4 each There are machined pockets at each of the four inside winch base corners that fit a flange head whiz nut Place a nut into each pocket and cent...

Page 7: ...it create certain hazards Self recovery that is safe for you bystanders and the environment requires product knowledge planning and practice Be aware there are specific techniques and hazards associa...

Page 8: ...x 6 6 11 22 570mm x 168mm x 285mm 63 5 lbs 28 8 kgs 10 x 4 5 254mm x 114 3mm Q9000 Winch with Synthetic Winch Line Rated Line Pull Single Line Gear Reduction Ratio Motor Series Wound Drum Size Dyneem...

Page 9: ...ith switch pressed If voltage present replace motor Water has entered motor Drain and dry Run in short bursts without load until completely dry Motor runs too hot long period of operation Let winch co...

Page 10: ..._____________________ ____________________________ ____________________________ ____________________________ ____________________________ ____________________________ ____________________________ ____...

Page 11: ...in or attempted repair or service by anyone not authorized by Quadratec b normal wear tear cosmetic damage or damage from moisture or water immersion c Acts of God accidents misuse including overload...

Page 12: ...The Trusted Source...

Reviews: