Yosemite Wood Stove
7004-187L
B. Clearances to Combustibles
A
B
BACK WALL/SIDE WALL
C
C
Fuel Door
Side
BACK WALL/SIDE WALL
B
ALCOVE SIDE VIEW
D
A
ALCOVE SIDE VIEW
NOTE: Clearances may only be reduced by means
approved by the regulatory authority having jurisdiction
Fire Risk.
• Comply with all minimum clearances to
combustibles as specifi ed.
• Failure to comply may cause house fi re.
WARNING
A B C
D
SINGLE WALL PIPE - A, B, and C Dimensions are based off of standard 18”
stove pipe clearance to combustible or unit certified clearances,
whichever is greater.
DOUBLE WALL PIPE - A, B, and C dimensions are based off of certification
clearances. Stove pipe manufacture clearances MUST be adhered to if they
exceed certified unit clearances.
* FOLLOW PIPE MANUFACTURES CLEARANCES AS REQUIRED
MINIMUM CLEARANCES TO COMBUSTIBLE MATERIALS in inches & (Millimeters)
NOTE: All A, B, and C Dimensions are to the center of the flue collar
For alcove only:
Six inch diameter listed Double wall air insulated connector
pipe with UL103 HT listed factory built Class A chimney or masonry chimney.
Maximum depth of Alcove shall be no more than 48 inches (1220mm) with a min-
imum height of 48 inches (1220mm) to top of unit and the referenced clearances.
Canada must comply with CAN/ULC-S269 M87 for the 650° factory built chimney
INSTALLATION: FULL VERTICAL OR ALCOVE
IF SIDE FUEL LOADING DOOR IS NOT USED:
- It must remain in the locked position at all times
- Use clearances for non-fuel door side for both sides
Non-Fuel Door Side
15.5 (393.7)
22.5 (571.5) 21.5 (546.1) 59 (1499)
Fuel Door Side
15.5 (393.7)
28.5 (723.9) 23.5 (596.9) 59 (1499)
Non-Fuel Door Side
13.5 (342.9)
22.5 (571.5) 14.5 (368.3) 59 (1499)
Fuel Door Side
13.5 (342.9)
28.5 (723.9) 23.5 (596.9) 59 (1499)
D
STOVE TO CEILING
CLEARANCE
*
4 in.
(101.6mm)
Fuel door side
28.5 (723.9mm)
43.5 in.
(1110mm)
MANTEL
12” MAX
HORIZONTAL THROUGH WALL
TOP AND SIDE VIEW
Non-fuel door side
22.5 in (571.5mm)