Page 15
Yosemite Wood Stove
R
7004-187L
October 13, 2015
Items Needed for Installation
: 4 inch (102mm) diameter
fl ex pipe in the length as required for your installation; Phil-
lips screwdriver; Silicone sealant; Drills and saws necessary
for cutting holes through the wall or fl ooring in your home.
I
ncluded in Kit:
2 cable ties; oustide air termination cap;
mounting screws (Discard the remaining parts).
In Stove's Component Pack:
Outside air cover plate
F. Outside Air Kit Installation
NOTE:
If you plan to install the optional blower
AND
the
outside air kit, complete the installation of the
outside air kit
FIRST
.
1. Remove 3 phillips head screws from rear of stove.
2.
Using the phillips head screws, attach blower to lower
rear of stove, as shown.
Figure 15.3 & 15.4
3. Plug blower cord into a grounded outlet. Do not remove
ground prong from plug. Route power cord to avoid
heat from the stove, or other damage. Do not route
cord under or in front of appliance.
4. Adjust the blower speed control to the desired speed.
G. Installation Of Optional Blower
The blower is shipped fully assembled and ready for
installation.
OUTSIDE AIR
TERMINATION CAP
(contains rodent screen)
OUTSIDE AIR
INTAKE
COVER PLA
TE
OUTSIDE AIR
COVER PLATE
Figure 15.2
Figure 15.1
Figure 15.3
REAR SHIELD
BLOWER MOUNTING
FLANGE
BLOWER SPEED CONTROL
BLOWER
MOUNTING
FLANGE
REAR
SHIELD
Remove all materials from packing box and stove compo-
nent pack
.
1. Remove ash lip by using a 7/16” wrench and remove the
2 bolts underneath the ash lip. Carefully lower and set
aside.
2. Swing open ash removal door.
3. Remove 2 screws from the stove bottom. Place cover
over the air opening and secure with same 2 screws.
Figure 15.1.
4. Mount
the
fl ex fl ange (with pipe fi tting extending out),
over the intake air opening at the rear of the stove using
the four mounting screws supplied with the kit.
Figure
15.2
.
Cut a 4 inch (102mm) minimum hole in the fl oor or wall to
accommodate outside air piping. Use 4 inch (102mm) metal
fl ex or rigid piping to directly connect outside air to the unit
or into
vented
crawl space.
(Do not put fl ex into a non-
vented crawl space).
If using fl ex tubing attach cable ties to secure tubing at both
ends. Use the supplied termination cap with a rodent screen.
Seal between the fl oor or wall and the pipe with silicone to
prevent moisture penetration.
Figure 15.4