Voyageur Grand

A. Outside Air Kit Installation

Items Needed for Installation (not supplied)

  •  102 millimeter flex aluminum pipe, or if using alternate mate

-

rial, then it shall be made from durable, non-combustible, 

heat  resistant  material  up  to  177°C.    Cut  the  pipe  to  the 

required length for your installation. 

  • Phillips head screw driver  
  • Silicone sealant

Figure 19.1 

  

A source of air (oxygen) is necessary in order for combustion to 

take place.  Whatever combustion air is consumed by the fire 

must be replaced.  Air is replaced via air leakage around win

-

dows and under doors. In homes that have tightly sealed doors 

and windows, an outside air source is needed. An optional Out

-

side Air Kit is avail

able. 

WARNING

Do not draw outside combustion air from:
•  Wall, floor or ceiling cavity

•  Enclosed space such as an attic or garage

•  Close proximity to exhaust vents or 

chimneys

Fumes or odor may result

Fire Risk
Asphyxiation Risk

Asphyxiation Risk

Length of outside air supply duct shall NOT exceed 

the length of the vertical height of the exhaust flue.

• 

Fire will not burn properly

  Smoke spillage occurs when door is opened due 

to air starvation.

WARNING

Option One - Outside Air Installation Instructions

1.  Swing grille down to expose the two screws.  

Figure 

19.1

2.  Remove the two screws and pull the access assembly 

away from the appliance.

3.  Assemble the outside air cover plate A  supplied in com

-

ponent pack.

4.  Re-install the access assembly. 

5.  Remove the outside air cover plate B on outer can and dis

-

card.   

Figure 19.2

6.  Install  optional  flex  adapter  to  outer  can  with  the  same 

screws.  Do not use plastic wire ties that come with the kit as 

they will melt.  NOTE:  You may need to install the flex pipe 

into the firebox first depending on installation. Attach flex to 

adapater with at least 2 screws.

7.  Ensure existing access hole in fireplace is sufficient to feed 

the 102 mm flex.

8.  After sliding can into fireplace, feed flex into cut opening to 

obtain outside combustion air.

9.  Level outer can and install appliance.  See 

page 20.

Option Two - Outside Air Installation Instructions

1. Follow steps 1-5 in Option One above
2.  Ensure existing acces hole in fireplace will not be covered by 

the outer can. Existing outside air intake hole may be under 

at the rear or side of outer can.  Outside air may also enter 

down existing chimney chase in some situations.

3.  Repeat step 9 under Option One with one exception.  After 

installing the appliance in the outer can, seal the fireplace 

opening and trim package with insulation to prevent air leak

-

age into the room.

Outside air inlet must be located to prevent blockage from:

•  Leaves, snow, ice or other debris

Block may cause combustion air starvation
Smoke spillage may set off alarms or irritate sensitive indi

-

viduals.

WARNING

Asphyxiation Risk

Grille hinges 

downward

Remove Screws & 

Pull Access Assembly 

away from Insert

Remove Outside Cover 

Plate A 

(Discard)

Outside Air Cover 

Plate B 

(Discard)

Termination 

Cap

Flex Adapter

Figure 19.2 

  

Remove the zip tie to the lower 

access cover.  It is to prevent the 

cover opening during shipping.

7

Appliance Set-up

Summary of Contents for VOYAGEUR GRAND INSERT GRAND-MBK-AU

Page 1: ...ngle between 0 30 inclusive For installations with a ceiling angle greater than 30 refer to Fig 18 1 21 1 21 2 and AS NZS 2918 2001 4 6 3 b Ceiling Plate may vary in size depending on ceiling angle Pl...

Page 2: ...joyment in the warmth and comfort of your hearth appliance Thank you for choosing Quadra Fire VOYAGEUR GRAND Serial No 007057 U S ENVIRONMENTAL PROTECTION AGENCY Export stove May not be operated withi...

Page 3: ...nces A Appliance Dimensions 16 B Clearances to Combustibles UL and ULC and Hearth Protection Requirements 17 C Alternate Floor Protection Calculation 18 Section 6 Chimney Systems A Venting Systems 19...

Page 4: ...OW HIGH BURN RATE CONTROL Upper Right Corner LOAD WOOD ADD NEWSPAPER ADD KINDLING ADD MORE WOOD SECURELY LATCH THE DOOR 4 LIGHT THE PAPER OPEN AIR CONTROLS REDUCE AIR CONTROL Set to desired heat outpu...

Page 5: ...burn rate instructions below and refer to Figure 5 1 NOTE These are guidelines Actual settings may vary with type of wood chimney draft altitude and other variables E Blower Control Box Snap Disc Oper...

Page 6: ...within close proxim ity approximately 4 ft 1 2m of appliance Can reverse air flow blowing hot air into appliance cavity Can damage appliance blower due to overheating 6 The blower is equipped with a...

Page 7: ...rom the firebox It is also recommended that before each heating season the entire system be professionally inspected cleaned and repaired if necessary WARNING Risk of Fire Do not use chimney cleaners...

Page 8: ...way open for 15 20 min utes should remove the built up coating E Glass Cleaning CAUTION Handle glass assembly with care Glass is breakable Avoid striking scratching or slamming glass Avoid abrasive c...

Page 9: ...he ashes in a non combustible container Firebrick is designed to protect your firebox After ashes are removed inspect the fire brick and replace firebricks that are crum bling cracked or broken WEEKLY...

Page 10: ...ding a Fire Section Check for adequate vent height refer to Chimney Height Section Open window below the appliance towards the wind Wood condition is too wet too large Use dry seasoned wood refer to S...

Page 11: ...by impact or misuse WARNING Risk of Fire or Injury Use only glass that is specified in the manual DO NOT replace with any other material Glass breakage will occur CAUTION Handle glass with care Inspec...

Page 12: ...ld down bracket s screws are completely seated in the grom ments Insert the locating tab in the hold down bracket into the placement slot Shock Risk Do NOT remove grounding prong from plug Plug direct...

Page 13: ...right side Remove the baffle boards and ceramic blanket together Figure 9 3 4 Re install in reverse order Be sure the baffle boards and ceramic blanket are in their proper positions E Door Handle Ass...

Page 14: ...oil for at least 15 minutes before trying to remove them 4 Slide the tube channel assembly all the way to left until it is off the threads Drop the right side down then slide the assembly back to righ...

Page 15: ...act your dealer if any irregularities are noticed 3 All safety warnings have been read and followed 4 This Owner s Manual has been read 5 Floor protection requirements have been met 6 Venting is prope...

Page 16: ...l Sizes A B Metal Surround w Cast Trim STD 1080 mm 762 mm Metal Surround w Cast Trim LRG 1219 mm 864 mm All Cast Surround 1016 mm 762 mm Metal Surround w Standard Trim STD 1092 mm 787 mm Metal Surroun...

Page 17: ...QUIREMENT FIREPLACE FRONT SURFACE SIDE TRIM 3 max depth SIDE WALL MANTEL 12 max depth TOP TRIM 3 4 max depth MANTEL DEFLECTOR REQUIRED MINIMAL REQUIREMENT FOR EXTENSION PROTECTION THE HEARTH THERMAL P...

Page 18: ...AS NZS 2198 2001 3 2 3 B Clearances to Combustibles Cont d Required Protection Suggested Protection NOTE Keep Ashlip Clear of Ashes NOTE Clearances may only be reduced by means approved by the regula...

Page 19: ...eable for cleaning and re installation NOTE Refer to chimney liner manufacturer for recom mendations on supporting the liner Installation into fireplaces without a permit will void the listing A Venti...

Page 20: ...he safety of your insert by directing the hot gases up the flue but will also help increase the unit s efficiency and decrease creosote deposits in the chimney When a connected flue or liner is in use...

Page 21: ...ont of Smoke Chamber Damper Plate Removed or Fastened in Open Position Seal with Non Combustible Material Minimum Clearance in Accordance with Insert Listing Floor Protection in Accordance with Insert...

Page 22: ...ssembly 5 Remove the outside air cover plate B on outer can and dis card Figure 19 2 6 Install optional flex adapter to outer can with the same screws Do not use plastic wire ties that come with the k...

Page 23: ...install the screws to secure in place D Leveling Legs B Optional Elbow Flue Adapter Installation Optional use of a Simpson Duravent 15 Universal Elbow Part Number 4615 may be purchased directly throu...

Page 24: ...ance top Secure in place Figure 21 2 7 Use the strain relief in the surround side for blower cord installation and use the cover plug to insert into the hole where the blower cord is not installed Fig...

Page 25: ...wered 102 to 152 millimeters long Phillips head screw driver pliers G Standard Surround Cast Trim Kit 4 Felt Vibration Insulation Pads Secure Surrounds to Cast Trim Kit Attach Magnet before installing...

Page 26: ...le Remove the shield and re install using the second right hole Figure 43 2 5 Position the trim on the appliance matching up the mounting brackets with the slots on the appliance 6 Attach the surround...

Page 27: ...the 2 screws at the top of the control plate Push the bottom of the control plate to the inside of the appliance and partially remove the control plate assembly White Wire Black Wire Figure 24 2 5 Loc...

Page 28: ...ire 11 Connect the white wire on the power cord into the fiber wrapped wire on the wire harness Connect the black wire on the power cord to the white wire on the rheostat Re attach the green ground te...

Page 29: ...WHERE SUCH ACTION IS CONSIDERED THE MAN UFACTURER SHOULD BE CONSULTED IN THE FIRST INSTANCE CAUTIONS CRACKED AND BROKEN COMPONENTS e g GLASS PANELS OR CERAMIC TILES MAY RENDER THE INSTALLATION UNSAFE...

Page 30: ...rage under this manufacturer s warranty begins on the date of first occupancy of the dwelling or six months after the sale of the product by an independent authorized HHT dealer distributor whichever...

Page 31: ...plied with the appliance or any other components not expressly authorized and approved by HHT 8 modification of the appliance not expressly authorized and approved by HHT in writing and or 9 interrupt...

Page 32: ...CC DO NOT DISCARD THIS MANUAL CAUTION Important operating and maintenance instruc tions included Leave this manual with party responsible for use and operation Read understand and follow these instruc...

Reviews: