Quadra-Fire Village Collection • QVI30, QVI35 • 340-901EF Rev. B • 2/06
Installing the Insert
(continued)
!
Figure 10. Fan Wiring Diagram
WARNING: DO NOT CONNECT 110-120 VAC TO
THE WALL SWITCH OR THE CONTROL VALVE
WILL BE DESTROYED.
CAUTION: LABEL ALL WIRES PRIOR TO DISCONNEC-
TION WHEN SERVICING CONTROLS. WIRING ERRORS
CAN CAUSE IMPROPER AND DANGEROUS OPERA-
TION. VERIFY PROPER OPERATION AFTER SERVICING.
NOTE:
IF ANY OF THE ORIGINAL WIRE AS SUP-
PLIED WITH THE APPLIANCE MUST BE RE-
PLACED, IT MUST BE REPLACED WITH TYPE
105
0
C RATED WIRE.
REMARQUE :
S'IL S'AVÈRE NÉCESSAIRE
DE REMPLACER LE FILAGE ORIGINAL TEL
QUE FOURNI AVEC L'APPAREIL, UTILISEZ
DU FILAGE DE TYPE 105°C.
Figure 10. Schéma de filage du ventilateur
Installation de la cassette
(suite)
!
AVERTISSEMENT : NE BRANCHEZ PAS DE
COURANT DE 110-120 VCA À L’INTERRUP-
TEUR MURAL DE COMMANDE. CELA
DÉTRUIRAIT LA VALVE DE COMMANDE.
ATTENTION : ÉTIQUETEZ TOUS LES FILS AVANT DE
LES DÉBRANCHER POUR LE SERVICE DES COM-
MANDES. LES ERREURS DE FILAGE RISQUENT
D’ENTRAÎNER UN FONCTIONNEMENT ANORMAL ET
DANGEREUX. VÉRIFIEZ LE BON FONCTIONNEMENT
DE L’APPAREIL APRÈS CHAQUE SERVICE.
FAN
(VENTILATEUR)
TEMPERATURE
SENSOR SWITCH
(
)
INTERRUPTEUR DE
DETECTION THERMIQUE
SPEED CONTROL
(RHEOSTAT)
(COMMANDE DE VITESSE)
(RHEOSTAT)
JUNCTION BOX
(BOITE DE DERIVATION)
BLACK
(NOIR)
BLACK
(NOIR)
BLACK
(NOIR)
BL
A
C
K
(N
O
IR)
BLACK
(NOIR)
BL
ACK
(N
O
IR)
BL
A
C
K
(N
O
IR)
BLACK
(NOIR)
GREEN
(VERT)
BLACK
(NOIR)
110-120 VAC
(110-120 V CA)
WHITE
(BLANC)
WHITE
(BLANC)
W
HIT
E
(B
LA
N
C
)
BLACK
(NOIR)
BLOWER RECEPTACLE
(PRISE DU VENTILATEUR)
BLOWER
(VENTILATEUR)
VARIABLE SPEED CONTROL
(COMMANDE DE
VITESSE VARIABLE)
GROUND
(TERRE)
TEMPERATURE SENSOR SWITCH
(
)
INTERRUPTEUR DE
DÉTECTION THERMIQUE
FAN WIRING DIAGRAM
(SCHEMA DE FILAGE DU VENTILATEUR)
JUNCTION BOX
(BOITE DE DERIVATION)