Quadra-Fire Village Collection  •  QVI30, QVI35  •  340-901EF  Rev. B  •  2/06

!

!

Installing the Insert 

(continued)

Step 9
Before Lighting the Appliance

Before

 lighting the appliance, do the following:

Review safety warnings and cautions

Read the 

Safety and Warning Information

 section at

the beginning of this 

Installers Guide

.

Double-check for gas leaks

Before lighting the appliance, double-check the unit for
possible gas leaks.

Double-check vent terminations and front grilles for
obstructions.

Before lighting the appliance, double-check the unit for
possible obstructions that could be blocking the vent
terminations or the front grilles.

Double-check for faulty components

Any component that is found to be faulty 

MUST BE

replaced with an approved component. Tampering with
the appliance components is 

DANGEROUS

 and voids

all warranties.

A small amount of air will be in the gas supply lines. When
first lighting the appliance, it will take a few minutes for the
lines to purge themselves of this air. Once the purging is
complete, the appliance will light and will operate normally.
Subsequent lightings of the appliance will not require this
purging of air from the gas supply lines,

 unless

 

the gas

valve has been turned to the OFF position

, in which

case the air would have to be purged.

The insert has an adjustable primary air shutter for control-
ling the primary air to the burner. THIS SHOULD BE AD-
JUSTED BY A QUALIFIED INSTALLER AT THE TIME OF
INSTALLATION. The shutter may need to be adjusted in
certain high vertical or high altitude installations to improve
the flame appearance.

The adjustment is located on the top of the control panel,
set back in a notch about 3/8". Loosen the ¼” screw a cou-
ple of turns and slide the screw to the right to close the
shutter and to the left to open the shutter. Retighten the
screw after adjustment is complete. If the screw is all the
way to the right the shutter is completely closed (0"). DO
NOT RUN THE INSERT WITH THE SHUTTER COMPLETE-
LY CLOSED. If the screw is all the way to the left the shut-
ter is completely open (3/4"). Moving the screw a ¼” will
move the air shutter a ¼”.

WARNING: 

 Closing the air shutter too much will cause

tall flames and improper burning of the gas. Soot depos-
its on the logs or glass are an indication of too little pri-
mary air. Open the shutter in this situation.

Installation de la cassette 

(suite)

Étape 9
Avant d’allumer l’appareil

Avant

 d’allumer le foyer, effectuez les opérations suivantes :

Revisez les consignes de sécurité et les mises en garde.

Lisez la section 

Consignes de sécurité et mises en

garde

 au début de ce 

Guide d’installation

.

Vérifiez qu’il n’y ait pas de fuites de gaz.

Avant d’allumer l’appareil, vérifiez à nouveau qu’il ne
présente pas de fuites de gaz.

Vérifiez qu’il n’y ait pas d’obstructions dans les
terminaisons du système d’évacuation et dans les
grilles avant.

Avant d’allumer l’appareil, vérifiez une fois de plus qu’il
n’y ait pas d’obstructions dans les terminaisons du
système d’évacuation et dans les grilles avant de
l’appareil.

Vérifiez qu’il n’y ait pas d’éléments défectueux.

Tout élément défectueux 

DOIT ÊTRE

 remplacé par un

élément approuvé. Il est 

DANGEREUX

 de modifier les

éléments de l’appareil et ceci annule toutes les garanties.

Les conduits à gaz contiendront une petite quantité d’air.
La première fois que vous allumerez l’appareil, il faudra
quelques minutes pour que les conduits se purgent de cet
air. Une fois la purge terminée, l’appareil s’allumera et
fonctionnera normalement.

Les prochaines fois que vous allumerez l’appareil, les conduits
à gaz ne contiendront pas d’air à évacuer, 

à moins que la

valve de commande n’ait été fermée

. Dans ce cas, l’air

devra être évacué.

La cassette est dotée d'un obturateur d'air primaire réglable
qui permet de contrôler l'arrivée d'air primaire dans le brûleur.
CET OBTURATEUR DOIT ÊTRE RÉGLÉ PAR UN
INSTALLATEUR QUALIFIÉ AU MOMENT DE
L'INSTALLATION. Il peut s'avérer nécessaire d'ajuster
l'obturateur pour certaines installations en hauteur ou à
haute altitude afin d'améliorer l'apparence de la flamme.

Le dispositif de réglage se trouve en haut du panneau de
commande, dans un renfoncement d'environ 9,5 mm (3/8
po). Desserrez la vis de 6,4 mm (¼ po) de quelques tours et
faites-la glisser vers la droite pour fermer l'obturateur ou vers
la gauche pour l'ouvrir. Reserrez-la une fois le réglage effectué.
Si la vis est complètement à droite, l'obturateur est complète-
ment fermé 0 mm (0 po). N'UTILISEZ PAS LA CASSETTE
LORSQUE L'OBTURATEUR EST COMPLÈTEMENT FERMÉ.
Si la vis se trouve complètement à gauche, l'obturateur est
complètement ouvert (19 mm [3/4 po]). Si vous déplacez la vis
de 6,4 mm (¼ po), l'obturateur d'air fait de même.

AVERTISSEMENT :

 Un obturateur d'air trop fer-

mé produit des flammes hautes et nuit à la com-

bustion du gaz. Des dépôts de suie sur les bûches ou
la vitre indiquent un manque d'air primaire. Il est possi-
ble de remédier à ce problème en ouvrant l'obturateur.

Summary of Contents for Village QVI30

Page 1: ...liquides inflammables proximit de cet appareil ou de tout autre appareil QUE FAIRE SI VOUS SENTEZ UNE ODEUR DE GAZ Ne tentez d allumer aucun appareil Ne touchez aucun interrupteur lectrique N utilise...

Page 2: ...technicien de service qualifi L appareil et le syst me d vacuation doivent tre INSPECT S avant la premi re utilisation et au moins unefoisl anparuntechnicienprofessionnel Unnettoyage plus fr quent peu...

Page 3: ...aintenez l avant de l appareil D GAG de tout obstacle et mat riau afin d en permettre le service et le bon fonctionnement En raison de la temp rature lev e l appareil doit SE TROUVER en dehors des zon...

Page 4: ...ection 5 Troubleshooting 36 Warranty 40 Table of Contents Consignes de s curit et mises en garde 2 Liste des pi ces de rechange 5 Section 1 Homologations et codes 10 Homologations et codes 10 Homologa...

Page 5: ...umber list on following pages La liste des num ros de pi ce se trouve la page suivante 10 6 9 11 7 12 13 14 4 5 NG LP Exploded Parts Diagram GN PL Vue clat e des pi ces Service Parts QVI35 QVI30 Begin...

Page 6: ...ve 705 420 Left Panel Extension Gauche Panneau Prolongement 330 265 Right Panel Extension Droit Panneau Prolongement 330 266 Glass Latch Assembly Ensemble de loquet vitr e 386 122A Regulator NG R gula...

Page 7: ...ve 705 420 Left Panel Extension Gauche Panneau Prolongement 340 265 Right Panel Extension Droit Panneau Prolongement 340 266 Glass Latch Assembly Ensemble de loquet vitr e 386 122A Regulator NG R gula...

Page 8: ...NG Valve GN 060 522 2 Valve LP Valve PL 060 523 3 Valve Bracket Parenth se de Valve 319 145 4 Tube Assembly Module de Tube 477 301A 5 Bottom Handle Poign e inf rieure 319 168 6 Top Handle Premi re Poi...

Page 9: ...che 1 SRV330 701 SRV340 701 2 Log 2 B che 2 SRV330 702 SRV340 702 3 Log 3 B che 3 SRV330 703 SRV340 703 4 Log 4 B che 4 SRV340 705 SRV340 704 5 Log 5 B che 5 SRV330 704 SRV340 706 6 Log 6 B che 6 SRV...

Page 10: ...lled in a bedroom or bed sitting room in the U S A and Canada Homologation de l appareil Les mod les Quadra Fire dont il est question dans ce Guide d installation ont t test s conform ment aux normes...

Page 11: ...this appliance at an elevation above 4 500 feet in Canada check with local authorities Installation haute altitude Les appareils gaz homologu s U L ont t test s et approuv s pour tre utilis s sans mo...

Page 12: ...AZARD Comment d buter Pr sentation des appareils gaz Quadra Fire Les appareils gaz vacuation directe Quadra Fire sont con us pour aspirer tout l air de combustion de l ext rieur de l difice et expulse...

Page 13: ...chemin es en mat riaux non com bustibles en ma onnerie ou pr fabriqu es combustible solide qui ont t install es conform ment aux codes de construction nationaux provinciaux et locaux 2 Les sp cificat...

Page 14: ...once installed on insert 7 Afin d obtenir des performances une s curit et une efficacit optimales les cassettes doivent tre install es avec un rev tement de conduit approuv conform ment aux codes CAN...

Page 15: ...er des accessoires facultatifs dispositifs tels qu un interrupteur mural ou une commande distance Figure 1 Sch ma Comment d buter suite 6 1 16 153 8 2 19 32 65 9 A 5 5 32 130 7 2 5 16 58 4 2 5 32 54 9...

Page 16: ...STARTING COLLAR COLLIER DE DEPART D ECHAPPEMENT LOW VOLTAGE WIRES FILS DE BASSE TENSION ON OFF SWITCH INTERRUPTEUR MARCHE ARRET MINIMUM APPLIANCE SIZE DIMENSIONS MINIMUM DE L APPAREIL Location QVI35 Q...

Page 17: ...tion Pr cautions d installation du syst me d vacuation Avant de commencer installer les modules d vacuation l installateur doit lire ces instructions et celles des modules d vacuation afin d obtenir u...

Page 18: ...30 LINK DV4 30B TABLE 1 Installation de la cassette suite REMARQUE Il sera peut tre n cessaire de d monter le registre de la chemin e en ma onnerie pour permettre l installation du conduit flexible AV...

Page 19: ...61 De 9 12 10 12 76 De 10 12 11 12 99 De 11 12 12 12 122 De 12 12 14 12 152 De 14 12 16 12 183 De 16 12 18 12 213 De 18 12 20 12 229 De 20 12 21 12 244 Installation de la cassette suite AVERTISSEMENT...

Page 20: ...HECHIMNEY Figure 4 Figure 4 Installation de la cassette suite AVERTISSEMENT LE CONDUIT D VACUA TION DOIT TRE RACCORD SEULEMENT AU COLLETDERACCORDDUSYST MED VACUATION DE L APPAREIL ET AU COLLET CENTRAL...

Page 21: ...G COLLAR COLLET DE RACCORD DU CONDUIT D ADMISSION D AIR TERMINATION CAP CAPUCHON ADAPTOR RACCORD EXHAUST COLLAR COLLET D EVACUATION INLET AIR COLLAR COLLET D ADMISSION D AIR STARTING COLLAR BRACKET CO...

Page 22: ...10 mm STANDING PILOT VEILLEUSE Figure 7 Gas Controls Systems Figure 7 Syst mes de commande de gaz tape 2 Emplacement nivellement et solidification de la cassette Installation de la cassette suite 1 Pl...

Page 23: ...nstallation doit tre effectu e par un technicien qualifi et ou muni d une licence de mani re re specter les r glements municipaux Dans la r publique de Massachusetts l installation doit tre effectu e...

Page 24: ...tem at test pressures equal to or less than one half 1 2 psig 3 5 kPa Installing the Insert continued Step 5 Gas Pressure Requirements Installation de la cassette suite tape 5 Sp cifications de la pre...

Page 25: ...TION D BRANCHEZ LES COMMANDES DIS TANCE SI VOUS VOUS ABSENTEZ POUR DES P RI ODES PROLONG ES DE CETTE FA ON LE FOYER NE POURRA PAS S ALLUMER ACCIDENTELLEMENT Filage de l allumage par veilleuse Sp cific...

Page 26: ...AS DE COURANT DE 110 120 VCA L INTERRUP TEUR MURAL DE COMMANDE CELA D TRUIRAIT LA VALVE DE COMMANDE ATTENTION TIQUETEZ TOUS LES FILS AVANT DE LES D BRANCHER POUR LE SERVICE DES COM MANDES LES ERREURS...

Page 27: ...place the glass door Slide the top tabs on the glass door into the slots on top of the firebox On the QVI35 slide the top tabs under the top spring latches Rotate the bottom of the glass door toward t...

Page 28: ...11 Glass Assembly Figure 12 Placement of the Ember Material 1 Soulevez la porte de garniture pour la retirer de l appareil 2 D verrouillez et retirez la porte en verre de l appareil Figure 10 Porte e...

Page 29: ...TIREZ L ENSEMBLE DE LAPORTE DE GARNITURE AVANT ET LA PORTE EN VERRE DE LA CASSETTEAVANT D INSTALLER L ENTOURAGE 1 Rep rez les fils de basse tension enroul s sur la cassette Voir Figure 13 2 Faites mon...

Page 30: ...tels or other combustible projections above the gas fireplace Figure 14 La Figure 14 repr sente la dimension minimale verticale et la dimension maximale horizontale correspondante des habillages ou au...

Page 31: ...n de la cassette suite tape 9 Avant d allumer l appareil Avant d allumer le foyer effectuez les op rations suivantes Revisez les consignes de s curit et les mises en garde Lisez la section Consignes d...

Page 32: ...inspect the appliance and to replace any part of the control system and any gas control which has been under water FOR YOUR SAFETY READ BEFORE LIGHTING WARNING IF YOU DO NOT FOLLOW THESE INSTRUCTIONS...

Page 33: ...aux commandes ouvrir la grille inf rieure 2 Mettre le bouton de la valve de commande sur ARR T Tourner le bouton dans le sens horaire jusqu VEILLEUSE l enfoncer et con tinuer le tourner dans le sens...

Page 34: ...tien et des services d pende de l utilisation et du type d installation il est conseill de demander un technicien de service qualifi d inspecter l appareil au d but de chaque saison de chauffage Vous...

Page 35: ...ADY NOT LIFTING OR FLOATING Entretien et service de votre appareil suite Figure 15 Forme des flammes du br leur ASSUREZ VOUS QUE LES FLAMMES SOIENTR GULI RES QU ELLESNE S L VENTPAS ETNE FLOTTENT PAS V...

Page 36: ...thermocouple copper lead Start the pilot and hold the valve knob in If the millivolt reading is less than 15mV replace the thermocouple b Defective valve If the thermocouple is producing more than 15...

Page 37: ...acer une des sondes d un voltm tre sur la pointe du thermocouple et l autre sonde sur le fil de cuivre du thermocouple Allumer la veilleuse et appuyer sur le bouton de la valve Si la tension est inf r...

Page 38: ...etting Adjust the air shutter located on the control panel c Debris around venturi Inspect the opening at the base of the burner NO MATERIAL SHOULD BE PLACED IN THIS OPENING 7 Flame burns blue and lif...

Page 39: ...bas d Porte vitr e mal ferm e et fuites aux coins des joints d tanch it Resserrer les coins e Thermopile ou thermocouple d fectueux Remplacer selon le besoin f Montage incorrect de la mitre S assurer...

Page 40: ...Hearth Home Technologies discontinues the model and two 2 years for optional accessories Adjustments regular maintenance cleaning and temporary repairs do not qualify for a service call fee and will...

Page 41: ...u un maximum de dix 10 ans apr s que Hearth Home Technologies cesse de produire le mod le et deux 2 ans pour les accessoires optionnels Les ajustements la maintenance r guli re le nettoyage et les r p...

Reviews: