April 18, 2018
7080-166B
13
TREKKER
This pellet heater has a manufacturer-set minimum low
burn rate that must not be altered. It is against federal
regulations to alter this setting or otherwise operate this
pellet heater in a manner inconsistent with operating
instructions in this manual.
3
Maintenance and Service
B. Quick Reference Maintenance Chart
NOTICE:
These are recommendations. When burning high ash content pellet fuel or a/pellet mix
you may need to clean the fire pot several times a day. Clean the stove and fire pot more
frequently if you encounter heavy build-up of ash at the recommended interval or you see
soot coming from the vent.
Not properly cleaning your appliance on a regular basis will
void your warranty
.
Shock and Smoke Hazard
• Smoke spillage into room can occur if appliance
is not cool before unplugging.
• Risk of shock if appliance not unplugged before
servicing appliance.
CAUTION
Follow the detailed instructions found in this section for each step listed as referenced in the
chart below
.
When properly maintained, your appliance will give you
many years of trouble-free service.
Contact your deale
r to
answer questions regarding proper operation, troubleshoot
-
ing and service for your appliance. Visit www.quadrafire.
com/owner-resources to view basic troubleshooting, FAQs,
use & care videos. We recommend annual service by a
qualified dealer.
Cleaning or Inspection
Frequency
Daily Weekly Monthly Yearly
Fire pot
As needed
OR
X
Ash Removal from Firebox
About 5 bags of fuel depend
-
ing on ash build-up
OR
X
Glass
When clear view of fire pot
becomes obscure
OR
X
Hopper
Every ton of fuel (50 bags)
OR
X
Exhaust Path, Drop Tube and Behind
Baffles
Every ton of fuel (50 bags) or
more frequently
OR
X
Door Handle & Gasket Inspection
Prior to heating season
OR
X
Blower, Convection
Every ton of fuel or more fre-
quently depending on perfor-
mance
OR
X
Blower, Exhaust
Every ton of fuel or more fre-
quently depending on perfor-
mance
OR
X
Firebox - Prepare for Non-Burn Season
At end of heating season
OR
X
Venting System
Every 3 tons of fuel or more
frequently depending on per-
formance
OR
X
A. Proper Shutdown Procedure
Turn user interface OFF, let appliance completely cool and
exhaust blower must be off. After cooling unplug appliance
before servicing.