18
09/20
7050-801E
SANTA FE FREESTANDING
C. Through The Wall & Vertical - Exterior
Figure 18.1
Figure 18.2
D. Vertical - Interior - Typical Installation
Figure 18.3
Firestop
Flashing
Rain Cap
6 in.
(152mm)
Min.
Non-combustible Hearth Pad
3 in. (76mm)
Min.
12 in.
(305mm)
Minimum
3 in. to 3 in.
(76-76mm)
Top Vent Kit
Clean-out Cover
on other side
Non-combustible Hearth Pad
Clean-out Cover
Tee
Wall Thimble
Support
Bracket
every 60 in.
(1.5m)
12 in.
(305mm)
Minimum
Rain Cap
Flashing
2 in. (51mm) minimum
6 in. (152mm)
Minimum
Firestop
Flashing
Rain Cap
6 in.
(152mm)
Minimum.
Non-combustible Hearth Pad
3 in. (76mm)
Minimum.
Cleanout Cover
12 in. (305mm)
Minimum
Ceiling Support
6 in. (152mm) Flue
Connector
6 in. (152mm) Class A
Chimney Connector
Adapter
3 in. to 6 in.
(76-152mm)
Top Vent Kit
All three installations are approved for mobile home
installations. Must use 3 or 4 inch (76 to 102mm) “L” or “PL”
Listed pellet venting or Listed double wall pipe and Quadra-
Fire Outside Air Kit in mobile homes. Single wall pipe is
approved for residential installations only.
B. Vertical into Existing Class A Chimney
*NOTE:
Clearance to combustibles are for standard
pellet pipe. If pellet pipe manufacturer allows
reduced clearances to their pipe, reduced
clearances are allowed.
NOTE:
A chimney connector shall not pass through an
attic or roof space, closet or similar concealed
space, or a floor or ceiling.