22
09/20
7050-801E
SANTA FE FREESTANDING
E. Optional Log Set Placement Instructions
2 Piece Log Set Installation
1.
Open door to expose the firebox.
2.
Install the left log first and then the right log
(
Figure 22.5).
3.
Lean the logs against the cast iron brick in the back of
the firebox.
4.
Push the logs to the far left and far right against the
sides of the firebox (
Figure 22.6).
5.
To clean the logs, use a vacuum and a soft brush
attachment or a paint brush.
Figure 22.6
Figure 22.5
NOTE:
Due to the abrasive nature of a pellet appliance
fire, the logs are not covered under warranty.
Any placement variation other than shown here
can cause excessive heat and shall void the
appliance warranty.
There is a 4 screw terminal block located on the back lower
left corner of the appliance directly above the power cord
inlet. The center 2 screws are for the thermostat wires (see
Figure 22.4
).
TERMINAL BLOCK
CENTER 2 SCREWS FOR
THERMOSTAT WIRES
POWER OUTLET
Figure 22.1
Figure 22.2
Figure 22.3
1. Separate the body of the thermostat from the
mounting plate by gently pulling the two pieces apart
(Figure 22.1)
2.
Use a drill with either a 3/16 drill bit for drywall or a 7/32
drill bit for plaster drill holes.
3. Using a hammer tap in wall anchors.
4. Route the wires through the opening in the base plate,
and hold the base against the wall while aligning up
to the holes. Attach base plate using a Phillips head
screwdriver and two screws.
5.
Connect your thermostat wire to the W and R terminals
(Figure 22.2)
.
W
R
W
R
Appliance
BATTERY
BATTERY
NOTE:
Ensure bare wire ends are held ALL the way
into the terminal block while the screws are
being tightened.
6.
There are two
AA ALKALINE ONLY
batteries
already installed into the thermostat; to activate,
remove black plastic tab that is located inside the
battery compartment.
7. Snap the thermostat to the base plate.
Figure 22.4
CAUTION
Logs are FRAGILE. Use extreme care when handling or
cleaning logs.