background image

17 August, 2018

 28

7075-177A

CONTACT INFORMATION 

Hearth & Home Technologies

352 Mountain House Road

Halifax, PA  17032

Division of HNI INDUSTRIES

Please contact your Quadra-Fire dealer with any questions or concerns. 

For the number of your nearest Quadra-Fire dealer

log onto www.quadrafire.com

DO NOT DISCARD THIS MANUAL

CAUTION

•  Important operating and 

maintenance  instruc-

tions included.

• 

Leave this manual with 

party responsible for use 

and operation.

• 

Read, understand and 

follow  these  instruc-

tions for safe installa-

tion and operation.

DO NOT

DISCARD

We recommend that you record the following pertinent

 information for your heating appliance.

Date purchased/installed:_________________________________________________________________________

Serial Number:____________________________________ Location on appliance:___________________________

Dealership purchased from:________________________________________ Dealer phone:_1(_____)_____-______

Notes:________________________________________________________________________________________

______________________________________________________________________________________________

______________________________________________________________________________________________

______________________________________________________________________________________________

This product may be covered by one or more of the following patents: (United States) 5341794, 5263471, 6688302, 7216645, 7047962 

or other U.S. and foreign patents pending.

Summary of Contents for GRAND-MBK-AU

Page 1: ...me room as appliance Alert children and adults to hazards of high temperatures High temperatures may ignite clothing or other flammable materials Keep clothing furniture draperies and other flammable materials away WARNING Fire Risk For use with solid wood fuel only Other fuels may over fire and generate poisonous gases i e carbon monoxide Do not store or use gasoline or other flammable vapors and...

Page 2: ...ry Built Fireplace 16 K Securing Chimney Components 16 L Altering the Fireplace 16 M Zero Clearance Fireplace 17 N Ovalizing Round Stainless Steel Liners 17 O Chimney Height Rise and Run 17 5 Appliance Set Up 18 A Outside Air Kit Installation 18 B Optional Offset Adapter Installation 19 C Securing Stove Pipe Liner to Flue Collar 19 D Leveling Legs 19 E Securing Appliance to Stove Pipe Liner 20 F S...

Page 3: ...r inconsistent with operating instructions in this manual NOTE Hearth Home Technologies manufacturer of this appliance reserves the right to alter its products their specifications and or price without notice Improper installation adjustment alteration service or maintenance can cause injury or property damage For assistance or additional information consult a qualified installer service agency or...

Page 4: ...ation plan consisting of at least two escape routes 5 A plan to deal with a chimney fire as follows 6 In the event of a chimney fire a Evacuate the house immediately b Notify fire department C Negative Pressure Negative pressure results from the imbalance of air available for the appliance to operate properly It can be strongest in lower levels of the house Causes include Exhaust fans kitchen bath...

Page 5: ...rocating saw Pliers Hammer Phillips screwdriver Flat blade screwdriver Plumb line Level Misc screws and nails Framing material High temp caulking material Gloves Framing square Electric drill and bits Safety glasses Tape measure 7 16 socket or wrench 1 2 3 4 in length 6 or 8 self drilling screws Installation and use of any damaged appliance Modification of the appliance Installation other than as ...

Page 6: ...appliance and given to the party responsible for use and operation Hearth Home Technologies recommends the following Photographing the installation and copying this checklist for your file That this checklist remain visible at all times on the appliance until the installtion is complete Comments Further description of the issues who is responsible Installer Builder Other Trades etc and corrective ...

Page 7: ...l Steel Surround SP GRAND STD and TRIMKIT 4331 Figure 7 5 Front View with Cast Surround SP GRAND CC 1295mm 864mm Figure 7 3 Front View with Large Steel Surround SP GRAND LRG and TRIMKIT 5134 Figure 7 1 Top View with Steel Surround 3 Dimensions and Clearances A Appliance Dimensions 124mm 124mm 602mm 602mm 830mm 830mm 459mm 459mm NOTE Flue Collar size is 152mm inside diameter ID ...

Page 8: ...rround and Optional 15 Degree Adapter DV 6DLR E15ADSS Figure 8 4 Side View with Cast Surround Figure 8 3 Side View with Steel Surround and Optional 15 Degree Adapter DV 6DLR E15ADSS Figure 8 2 Side View with Steel Surround and Optional 15 Degree Adapter DV 6DLR E15ADSS Figure 8 1 Side View with Steel Surround 30 30 686mm 686mm 385mm 385mm 655mm 655mm 359mm 359mm 154mm 154mm 73mm 73mm 597mm 597mm 6...

Page 9: ...ns Millimeters A Height 619 B Front Width Steel Surround 835 Front Width Cast Surround 835 C Back Width 610 D Depth Steel Surround 464 Depth Cast Surround 464 NOTE If trim measurement is over 19mm in depth use mantle or side clearances to combustibles NOTE Minimum opening dimensions include a 6mm clearance around unit Minimal requirement for extension protection The hearth thermal protection minim...

Page 10: ...onducted through the non combustible material to the combustible material beneath it The R value of a material must be equal or larger then the required R value to be acceptable Quadra Fire Voyageur Grand ACC does not require a insulating Floor Protector as they are tested and comply with the minimum Floor Protector requirements of AS NZS 2918 2001 NOTE Heat shield requirements for heat sensitive ...

Page 11: ...stall through the warm space enclosed by the building envelope This helps to produce more draft especially during lighting and die down of the fire Penetrate the highest part of the roof This minimizes the affects of wind turbulence and down drafts Consider the appliance location in order to avoid floor and ceiling attic joists and rafters Locate termination cap away from trees adjacent structures...

Page 12: ...moking or overdraft occurs NOTICE Locating the appliance in a basement or in a location of considerable air movement can cause intermittent smoke spillage from appliance Do not locate appliance near Frequently open doors Central heat outlets or returns WARNING Asphyxiation Risk DO NOT CONNECT THIS Appliance TO A CHIMNEY FLUE SERVICING ANOTHER APPLIANCE DO NOT CONNECT TO ANY AIR DISTRIBUTION DUCT O...

Page 13: ... have cracks loose mortar or other signs of deterioration and blockage Hearth Home recommends a certified pro fessional or a technician under the direction of a certified professional F Larger Chimneys Hearth Home recommended that chimneys with larger diameters than 152mm be fully relined An oversized flue can affect draft and impair performance and will allow increased build up of creosote WARNIN...

Page 14: ...lations into a clay flue without a stainless steel liner may reduce draw which affects performance will cause the glass to darken and produce excessive creosote and create start up issues The masonry wall of the chimney if brick or modular block must be a minimum of 102mm nominal thickness A chimney of rubble stone must be at least 305mm thick Should be lined with a 152mm stainless steel flue line...

Page 15: ...emove the damper 2 Seal damper area of chimney around chimney connector with a high temperature sealant or seal insert against the face of the fireplace 3 Both methods must be removable and replaceable for cleaning and re installation H Prefabricated Metal Chimney Minimum 203mm Masonry Thickness in Front of Smoke Chamber Damper Plate Removed or Fastened in Open Position Seal with Non Combustible M...

Page 16: ...best for your application The use of this connection method not only increases the safety of your insert by directing the hot gases up the flue but will also help increase the unit s efficiency and decrease creosote deposits in the chimney When a connected flue or liner is in use the insert is able to breathe better by allowing a greater draft to be created This great draft can decrease problems s...

Page 17: ...ow for the existing air cooled chimney system Re install original factory built chimney cap only See Section F Prefabricated Metal Chimney To prevent room air passage to the chimney cavity of the fireplace seal either the damper area around the chimney liner or the insert surround Circulating air chamber i e in a steel fireplace liner or metal hearth circulatory may not be blocked The air flow wit...

Page 18: ...adapter with at least 2 screws 7 Ensure existing access hole in fireplace is sufficient to feed the 4 inch flex 8 After sliding can into fireplace feed flex into cut opening to obtain outside combustion air 9 Level outer can and install appliance Option Two Installation Instructions 10 Swing grille down to expose the two screws Figure 18 1 11 Remove the two screws and pull the access assembly away...

Page 19: ...ravent 15 Universal Elbow Part Number 4615 may be purchased directly through your local Simpson Duravent Pipe Distributor or from your local Quadra Fire dealer Part Number DV 6DLR E15ADSS Figure 19 1 shows a vertical installation and also how to create an optional 30 elbow installation The 15 elbow may be secured directly to the flue collar Follow the pipe manufacturer s instructions for using scr...

Page 20: ...im Kit Installation Standard Size 109 22cm W x 78 74cm H Large Size 129 54cm W x 86 36cm H 1 Lay surround face down on a protected surface to prevent scratching 2 Using a 4 to 6 inches long Phillips head screw driver attach the side surrounds to the top surround using 2 8 sheet metal screws on each side provided with the kit Figure 20 3 3 Lay the trim face down and place the corner brackets into p...

Page 21: ...n the top cast piece and 2 bosses on each side piece 6 Secure the magnet to the bracket and attach the magnet and bracket to each metal side piece at the bottom The magnet is facing the front Figure 21 2 7 Place the cast footers under the metal sides aligning the top and bottom holes in the cast footers and metal sides 8 The 9 mounting clips are shipped in one long strip Hand break apart or use pl...

Page 22: ...lots on the appliance 6 Attach the surround to the appliance 2 screws 4 Mounting Brackets Mounting Brackets Attach to Appliance with Screws Remove and Reposition Side Shield using Second Hole Do not overtighten may damage porcelain finish Figure 22 1 Figure 22 2 I Blower Cord Installation on Left Side The blower cord is shipped to be installed on the right side of the appliance You may relocate th...

Page 23: ...se wires from the wire harness 6 Remove the screw that is holding the ground lug to the control plate 7 Use needle nose pliers to remove the strain relief that protects the power cord from the control plate 8 The power cord is now disconnected from the blower control plate Pull the cord out through the right side of the appliance Route Cord Through Retainer Clip Grommet 9 Insert the power cord thr...

Page 24: ...wire on the wire harness Connect the black wire on the power cord to the white wire on the rheostat Re attach the green ground terminal to the control plate 12 Insert the control plate assembly back into the appliance as shown Tilt the assembly forward and then lift up and rotate the bottom towards the front of the appliance at the same time ensure that the snap disc holder is properly seated Secu...

Page 25: ...75 177A VOYAGEUR GRAND AU Blower Access Assembly Grille hinges downward Remove Screws Pull Access Assembly away from Insert Hold Down Bracket Remove Screws from Hold Down Bracket and Pull Forward Placement Slot Figure 25 1 ...

Page 26: ...vice parts from your dealer or distributor Stocked at Depot ITEM DESCRIPTION COMMENTS PART NUMBER 25 Surrounds Cast Matte Black SP GRAND CC MBK 25 1 Surround Right Matte Black SRV7075 131MBK 25 2 Surround Top Matte Black SRV7075 129MBK 25 3 Surround Left Matte Black SRV7075 133MBK 25 4 Surround Retainer Qty 4 req SRV7063 136 25 5 1 4 20 x 50 Phillips Pan Head Screw Pkg of 12 32281 12 Y Component P...

Page 27: ...at Depot ITEM DESCRIPTION COMMENTS PART NUMBER 26 1 Trim Leg Right Matte Black 414 7130MBK 26 2 Trim Header Matte Black 414 7110MBK 26 3 Trim Leg Left Matte Black 414 7120MBK 26 4 Trim Footer Left Matte Black 414 7090MBK 26 5 Trim Footer Right Matte Black 414 7100MBK Component Pack SRV7063 055 Surrounds Metal Standard SP GRAND STD Large SP GRAND LRG Trim Kit Black TRIMKIT 4331 BK Gold TRIMKIT 4331...

Page 28: ...e purchased installed _________________________________________________________________________ Serial Number ____________________________________ Location on appliance ___________________________ Dealership purchased from ________________________________________ Dealer phone _1 _____ _____ ______ Notes ________________________________________________________________________________________ ______...

Reviews: